Heterophile antibodies are immunoglobulins produced by the immune system in response to exposure to animal and bacterial antigens, blood transfusions, autoimmune disorders, hematologic malignancies, dialysis, and pregnancy. Recently, these antibodies have garnered significant attention due to their impact on the accuracy of laboratory test results. Heterophile antibodies can bind not only to specific antigens but also to those from different species, including the antibodies used in laboratory tests. This cross-reactivity with foreign proteins is the basis for their interference in immunological assays, such as those measuring cardiospecific troponins (cTn). This manuscript reviews the literature on cases of heterophile antibody interference in troponin testing and proposes an algorithm for identifying such interference when clinical discrepancies arise. Recognizing and addressing heterophile antibody interference is crucial, particularly for tests like those for troponins, which are key biomarkers in the diagnosis and management of emergency and intensive care patients. The literature emphasizes the need for accurate procedures to distinguish true cardiac damage from false positives, thereby preventing unnecessary additional tests and hospitalizations.

Review of Literature and Recommended Procedures for Management of Unusual Cases of False Positive Troponin Tests / M. Salvatici, C. Sommese, M.M. Corsi Romanelli, L. Drago. - In: INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES. - ISSN 1422-0067. - 26:3(2025 Jan 26), pp. 1045.1-1045.12. [10.3390/ijms26031045]

Review of Literature and Recommended Procedures for Management of Unusual Cases of False Positive Troponin Tests

M.M. Corsi Romanelli;L. Drago
Ultimo
2025

Abstract

Heterophile antibodies are immunoglobulins produced by the immune system in response to exposure to animal and bacterial antigens, blood transfusions, autoimmune disorders, hematologic malignancies, dialysis, and pregnancy. Recently, these antibodies have garnered significant attention due to their impact on the accuracy of laboratory test results. Heterophile antibodies can bind not only to specific antigens but also to those from different species, including the antibodies used in laboratory tests. This cross-reactivity with foreign proteins is the basis for their interference in immunological assays, such as those measuring cardiospecific troponins (cTn). This manuscript reviews the literature on cases of heterophile antibody interference in troponin testing and proposes an algorithm for identifying such interference when clinical discrepancies arise. Recognizing and addressing heterophile antibody interference is crucial, particularly for tests like those for troponins, which are key biomarkers in the diagnosis and management of emergency and intensive care patients. The literature emphasizes the need for accurate procedures to distinguish true cardiac damage from false positives, thereby preventing unnecessary additional tests and hospitalizations.
cardiovascular risk; false positive; heterophile antibodies; troponin
Settore MEDS-03/A - Microbiologia e microbiologia clinica
Settore MEDS-02/B - Patologia clinica
26-gen-2025
Article (author)
File in questo prodotto:
File Dimensione Formato  
ijms-26-01045.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 596.29 kB
Formato Adobe PDF
596.29 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1162038
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact