The problems with reconstructing the trajectory of γ-rays and identifying their interaction points in segmented coaxial HPGe detectors are discussed here in view of their importance in the design of the next generation of detector arrays for γ-ray spectroscopy studies. In fact, the tracking quality of the γ-ray interactions in the medium controls the overall detection efficiency. This paper focuses on two main points. One is the study of how the tracking, reconstruction efficiency is affected by the ability of 'disentangle multiple interactions per segment. The other is the study of the consequences that different types of segmentation have on the overall efficiency. Two geometries have been chosen: that of a single cylindrical detector and that of a spherical shell.
Efficiency of segmented HPGe detectors: Design criteria for pulse shape analysis / O. Wieland, F. Camera, B. Million, A. Bracco, M. Pignanelli, G. Ripamonti, A. Geraci, J. Van Der Marel. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 48:3(2001 Jun), pp. 296-301. (Intervento presentato al convegno NSS Annual Nuclear Science Symposium : October, 15th - 20th tenutosi a Lyon (France) nel 2000) [10.1109/23.940069].
Efficiency of segmented HPGe detectors: Design criteria for pulse shape analysis
F. CameraSecondo
;A. Bracco;M. Pignanelli;
2001
Abstract
The problems with reconstructing the trajectory of γ-rays and identifying their interaction points in segmented coaxial HPGe detectors are discussed here in view of their importance in the design of the next generation of detector arrays for γ-ray spectroscopy studies. In fact, the tracking quality of the γ-ray interactions in the medium controls the overall detection efficiency. This paper focuses on two main points. One is the study of how the tracking, reconstruction efficiency is affected by the ability of 'disentangle multiple interactions per segment. The other is the study of the consequences that different types of segmentation have on the overall efficiency. Two geometries have been chosen: that of a single cylindrical detector and that of a spherical shell.| File | Dimensione | Formato | |
|---|---|---|---|
|
Efficiency_of_segmented_HPGe_detectors_design_criteria_for_pulse_shape_analysis.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Licenza:
Nessuna licenza
Dimensione
104.85 kB
Formato
Adobe PDF
|
104.85 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.