Aim: The aim of this work is firstly to verify the optional mechanical and biological properties of HA in vitro and in vivo, comparing to other synthetic materials. Secondly the CAD/CAM technique using porous HA scaffold was evaluated to estimate its real efficacy with clinical and radiological assessments. Materials and Methods: Inclusion criteria selected for the current study are 1) histological evaluation of the effective biocompatibility and osteoconductivity of porous HA in vivo and in vitro 2) evaluation of the mechanical properties of HA in relation to its porosity 3) compared evaluation of biological and mechanical properties between several biomaterials in order to assess whereas HA is preferable in relationship to different clinical situation 4) clinical and radiological evaluation of the precision of the CAD/CAM technique. Results Among the synthetic materials, hydroxyapatite has proved excellent osteoconductivity and biocompatibility in vitro and in vivo comparing to other biomaterials, porous hydroxyapatite (HA) is a more readily resorbable and more osteoconductive material than dense HA, however the strength decreases exponentially with the increase of the porosity. Mechanical tests showed that fabricated HA scaffolds with pore diameters ranging from 400 to 1200 microns had compressive modulus and strength within the range of human craniofacial trabecular bone; this implies that they can be easily used for bone regenerative rehabilitations. Conclusion: Several studies in vivo l-rave evaluate optimal clinical and radiological results using HA scaffold as grafts before implants position even after several months on both human mandibula and r:raxilla. In conclusion, using CAD/CAM technique for HA scaffold could increase grafts stability and reduce surgical operative time.

Computer aided design/computer aided manufacturing bone grafts for reconstruction in jawbone atrophy / U. Garagiola. ((Intervento presentato al convegno Magyar Arc-, Állcsont- és Szájsebészeti Társaság XXI Kongresszusa. XI Danubius Nemzetközi Kongresszus : 28-30 szeptember tenutosi a Debrecen nel 2017.

Computer aided design/computer aided manufacturing bone grafts for reconstruction in jawbone atrophy

U. Garagiola
2017

Abstract

Aim: The aim of this work is firstly to verify the optional mechanical and biological properties of HA in vitro and in vivo, comparing to other synthetic materials. Secondly the CAD/CAM technique using porous HA scaffold was evaluated to estimate its real efficacy with clinical and radiological assessments. Materials and Methods: Inclusion criteria selected for the current study are 1) histological evaluation of the effective biocompatibility and osteoconductivity of porous HA in vivo and in vitro 2) evaluation of the mechanical properties of HA in relation to its porosity 3) compared evaluation of biological and mechanical properties between several biomaterials in order to assess whereas HA is preferable in relationship to different clinical situation 4) clinical and radiological evaluation of the precision of the CAD/CAM technique. Results Among the synthetic materials, hydroxyapatite has proved excellent osteoconductivity and biocompatibility in vitro and in vivo comparing to other biomaterials, porous hydroxyapatite (HA) is a more readily resorbable and more osteoconductive material than dense HA, however the strength decreases exponentially with the increase of the porosity. Mechanical tests showed that fabricated HA scaffolds with pore diameters ranging from 400 to 1200 microns had compressive modulus and strength within the range of human craniofacial trabecular bone; this implies that they can be easily used for bone regenerative rehabilitations. Conclusion: Several studies in vivo l-rave evaluate optimal clinical and radiological results using HA scaffold as grafts before implants position even after several months on both human mandibula and r:raxilla. In conclusion, using CAD/CAM technique for HA scaffold could increase grafts stability and reduce surgical operative time.
set-2017
Settore MEDS-16/A - Malattie odontostomatologiche
Computer aided design/computer aided manufacturing bone grafts for reconstruction in jawbone atrophy / U. Garagiola. ((Intervento presentato al convegno Magyar Arc-, Állcsont- és Szájsebészeti Társaság XXI Kongresszusa. XI Danubius Nemzetközi Kongresszus : 28-30 szeptember tenutosi a Debrecen nel 2017.
Conference Object
File in questo prodotto:
File Dimensione Formato  
2017 Computer aided design - Hungarian association - Danubius.pdf

accesso aperto

Tipologia: Altro
Dimensione 1.61 MB
Formato Adobe PDF
1.61 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1122118
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact