Abnormal excess or lack of body mass can influence gait patterns, but in some cases such differences are subtle and not easy to detect, even with quantitative techniques for movement analysis. In these situations, the study of trunk accelerations may represent an effective way to detecting gait anomalies in terms of symmetry through the calculation of Harmonic Ratio (HR), a parameter obtained by processing trunk accelerations in the frequency domain. In the present study we used this technique to assess the existence of differences in HR during gait in a cohort of 75 healthy children and early adolescents (aged 7-14 years) stratified into 3 equally-sized age and gender-matched groups (Underweight: UW; Normal Weight: NW; Overweight: OW). The accelerometric signal, acquired using a single wearable inertial sensor, was processed to calculate stride length, speed, cadence and HR in antero-posterior, vertical and medio-lateral directions. No differences in spatio-temporal parameters were found among groups, while the HR in the medio-lateral direction was found significantly lower in UW children, while OW exhibited the highest values. On the basis of the results obtained, HR appears capable of discriminating gait symmetry in children with different body mass even when conventional gait parameters are unchanged.

Symmetry of Gait in Underweight, Normal and Overweight Children and Adolescents / V. Cimolin, N. Cau, A. Sartorio, P. Capodaglio, M. Galli, G. Tringali, B. Leban, M. Porta, M. Pau. - In: SENSORS. - ISSN 1424-8220. - 19:9(2019), pp. 2054.1-2054.11. [10.3390/s19092054]

Symmetry of Gait in Underweight, Normal and Overweight Children and Adolescents

P. Capodaglio;
2019

Abstract

Abnormal excess or lack of body mass can influence gait patterns, but in some cases such differences are subtle and not easy to detect, even with quantitative techniques for movement analysis. In these situations, the study of trunk accelerations may represent an effective way to detecting gait anomalies in terms of symmetry through the calculation of Harmonic Ratio (HR), a parameter obtained by processing trunk accelerations in the frequency domain. In the present study we used this technique to assess the existence of differences in HR during gait in a cohort of 75 healthy children and early adolescents (aged 7-14 years) stratified into 3 equally-sized age and gender-matched groups (Underweight: UW; Normal Weight: NW; Overweight: OW). The accelerometric signal, acquired using a single wearable inertial sensor, was processed to calculate stride length, speed, cadence and HR in antero-posterior, vertical and medio-lateral directions. No differences in spatio-temporal parameters were found among groups, while the HR in the medio-lateral direction was found significantly lower in UW children, while OW exhibited the highest values. On the basis of the results obtained, HR appears capable of discriminating gait symmetry in children with different body mass even when conventional gait parameters are unchanged.
Accelerometer; Gait; Harmonic ratio; Low disability; Obesity; Spatial-temporal parameters
Settore MEDS-19/B - Medicina fisica e riabilitativa
2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
sensors-19-02054.pdf

accesso aperto

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 910.05 kB
Formato Adobe PDF
910.05 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1118469
Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 27
  • OpenAlex ND
social impact