PURPOSE: We tested the hypothesis that the maximal lactate steady state (MLSS) can be accurately determined in healthy subjects based on measures of deoxygenated hemoglobin (deoxyHb), an index of oxygen extraction measured noninvasively by near-infrared spectroscopy (NIRS). METHODS: Thirty-two healthy men (mean ± SD age = 48 ± 17 yr, range = 23-74 yr) performed an incremental cycling test to exhaustion and square wave tests for MLSS determination. Cardiorespiratory variables were measured bbb and deoxyHb was monitored noninvasively on the right vastus lateralis with a quantitative NIRS device. The individual values of V̇O2 and HR corresponding to the MLSS were calculated and compared to the NIRS-derived MLSS (NIRSMLSS) that was, in turn, determined by double linear function fitting of deoxyHb during the incremental exercise. RESULTS: V̇O2 and HR at MLSS were 2.25 ± 0.54 L·min (76% ± 9% V̇O2max) and 133 ± 14 bpm (81% ± 7% HRmax), respectively. Muscle O2 extraction increased as a function of exercise intensity up to a deflection point, NIRSMLSS, at which V̇O2 and HR were 2.23 ± 0.59 L·min (76% ± 9% V̇O2max) and 136 ± 17 bpm (82% ± 8% HRmax), respectively. For both V̇O2 and HR, the difference of NIRSMLSS from MLSS values was not significant and the measures were highly correlated (r = 0.81 and r = 0.76). The Bland-Altman analysis confirmed a nonsignificant bias for V̇O2 and HR (-0.015 L·min and 3 bpm, respectively) and a small imprecision of 0.26 L·min and 8 bpm. CONCLUSIONS: A plateau in muscle O2 extraction was demonstrated in coincidence with MLSS during an incremental cycling exercise, confirming the hypothesis that this functional parameter can be accurately estimated with a quantitative NIRS device. The main advantages of NIRSMLSS over lactate-based techniques are the noninvasiveness and the time/cost efficiency.

Determination of maximal lactate steady state in healthy adults: Can NIRS help? / C. Bellotti, E. Calabria, C. Capelli, S. Pogliaghi. - In: MEDICINE AND SCIENCE IN SPORTS AND EXERCISE. - ISSN 0195-9131. - 45:6(2013), pp. 1208-1216. [10.1249/MSS.0b013e3182828ab2]

Determination of maximal lactate steady state in healthy adults: Can NIRS help?

C. Capelli
Penultimo
;
S. Pogliaghi
2013

Abstract

PURPOSE: We tested the hypothesis that the maximal lactate steady state (MLSS) can be accurately determined in healthy subjects based on measures of deoxygenated hemoglobin (deoxyHb), an index of oxygen extraction measured noninvasively by near-infrared spectroscopy (NIRS). METHODS: Thirty-two healthy men (mean ± SD age = 48 ± 17 yr, range = 23-74 yr) performed an incremental cycling test to exhaustion and square wave tests for MLSS determination. Cardiorespiratory variables were measured bbb and deoxyHb was monitored noninvasively on the right vastus lateralis with a quantitative NIRS device. The individual values of V̇O2 and HR corresponding to the MLSS were calculated and compared to the NIRS-derived MLSS (NIRSMLSS) that was, in turn, determined by double linear function fitting of deoxyHb during the incremental exercise. RESULTS: V̇O2 and HR at MLSS were 2.25 ± 0.54 L·min (76% ± 9% V̇O2max) and 133 ± 14 bpm (81% ± 7% HRmax), respectively. Muscle O2 extraction increased as a function of exercise intensity up to a deflection point, NIRSMLSS, at which V̇O2 and HR were 2.23 ± 0.59 L·min (76% ± 9% V̇O2max) and 136 ± 17 bpm (82% ± 8% HRmax), respectively. For both V̇O2 and HR, the difference of NIRSMLSS from MLSS values was not significant and the measures were highly correlated (r = 0.81 and r = 0.76). The Bland-Altman analysis confirmed a nonsignificant bias for V̇O2 and HR (-0.015 L·min and 3 bpm, respectively) and a small imprecision of 0.26 L·min and 8 bpm. CONCLUSIONS: A plateau in muscle O2 extraction was demonstrated in coincidence with MLSS during an incremental cycling exercise, confirming the hypothesis that this functional parameter can be accurately estimated with a quantitative NIRS device. The main advantages of NIRSMLSS over lactate-based techniques are the noninvasiveness and the time/cost efficiency.
functional evaluation; exercise prescription; non-invasive techniques; anaerobic metabolism
Settore BIOS-06/A - Fisiologia
2013
Article (author)
File in questo prodotto:
File Dimensione Formato  
Bellotti_et_al_2013.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 2.34 MB
Formato Adobe PDF
2.34 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1117956
Citazioni
  • ???jsp.display-item.citation.pmc??? 22
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 57
  • OpenAlex ND