Breath-by-breath (BbB) oxygen uptake rate (˙VO2 ) was measured at the mouth (MO) and at the alveolar level, at the onset of square wave cycling exercise of moderate intensity in six healthy male subjects. Alveolar BbB ˙VO2 values were calculated correctingMO ˙VO2 values by (i) estimating (GR); and (ii) measuring (opto-electronic plethysmography, OEP) BbB lung O2 store changes. ˙VO2 kinetics was then described by a bi-exponential model. GR yielded larger values of the time constants (2) of the primary phase of ˙VO2 kinetics. The mean response times (MRTs) calculated by analysing GR BbB ˙VO2 values were larger than (i) those obtained by using MO and OEP at 90W; and (ii) that by using MO at 120 W. OEP corrected ˙VO2 yielded the highest normalised amplitude of the cardiodynamic phase of the ˙VO2 on-response. Correction of BbB ˙VO2 for actual BbB changes of lung O2 stores by OEP thus seems more appropriate for the study of the early cardiodynamic phase of ˙VO2 kinetics than GR.

Pulmonary ˙VO2 kinetics at the onset of exercise is faster when actual changes in alveolar O2 stores are considered / A. Aliverti, B. Kayser, M. Cautero, R.L. Dellacà, P.E. di Prampero, C. Capelli. - In: RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY. - ISSN 1569-9048. - 169:1(2009), pp. 78-82. [10.1016/j.resp.2009.08.012]

Pulmonary ˙VO2 kinetics at the onset of exercise is faster when actual changes in alveolar O2 stores are considered

C. Capelli
Ultimo
2009

Abstract

Breath-by-breath (BbB) oxygen uptake rate (˙VO2 ) was measured at the mouth (MO) and at the alveolar level, at the onset of square wave cycling exercise of moderate intensity in six healthy male subjects. Alveolar BbB ˙VO2 values were calculated correctingMO ˙VO2 values by (i) estimating (GR); and (ii) measuring (opto-electronic plethysmography, OEP) BbB lung O2 store changes. ˙VO2 kinetics was then described by a bi-exponential model. GR yielded larger values of the time constants (2) of the primary phase of ˙VO2 kinetics. The mean response times (MRTs) calculated by analysing GR BbB ˙VO2 values were larger than (i) those obtained by using MO and OEP at 90W; and (ii) that by using MO at 120 W. OEP corrected ˙VO2 yielded the highest normalised amplitude of the cardiodynamic phase of the ˙VO2 on-response. Correction of BbB ˙VO2 for actual BbB changes of lung O2 stores by OEP thus seems more appropriate for the study of the early cardiodynamic phase of ˙VO2 kinetics than GR.
BbB V'O2 consumption; opto-electronic plethysmography; VO2 kinetics; Exercise; O2 lung stores; V'O2-on
Settore BIOS-06/A - Fisiologia
2009
Article (author)
File in questo prodotto:
File Dimensione Formato  
Aliverti_et_al_2009.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 385.02 kB
Formato Adobe PDF
385.02 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1117633
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
  • OpenAlex ND
social impact