The maximal explosive power during a two legs jump was measured on four competitive athletes [mean age 24 (SD 4.3) years, height 1.79 (SD 0.09) m; body mass 68.7 (SD 12.8) kg] at different starring knee angles (70, 90, 110, 130 and 150 degrees). The experiments were performed on a newly developed instrument with which both force and speed could be measured using a force platform and a wire tachometer, respectively, and on a conventional force platform. At the smallest knee angle (70 degrees) the mean power output (W radical anion in watts per kilogram) developed during the jump was found not to differ significantly between the two methods (P > 0.1). At the larger knee angles W radical anion was 18.4% (90 degrees), 34.5% (110 degrees), 47.4% (130 degrees) and 19.4% (150 degrees) higher using the conventional force platform (P < 0.05 throughout). The difference of W Radical anion between the two methods was attributed to the recovery of elastic energy due to the counter movement which immediately preceded the jump on the conventional platform, but not on the newly developed instrument. Indeed because of a mechanical arrangement which prevented the subject from moving towards the platforms, eccentric work (W-) could not be performed on the newly developed instrument; whereas Won the conventional force platform was almost negligible at 70 degrees knee angle [mean 1.7 (SD 2.3 J)] reached a maximum of 13.1 (SD 7.9)J at 130 degrees and decreased again to a mean 4.7 (SD 3.6) J for the largest angle (150 degrees). Furthermore, on the conventional force platform, the force at the onset of the positive speed phase (Fi) was an increasing function of W- (r(2) = 0.519, P < 0.001); and the difference of W Radical anion between the conventional and new instruments was larger the larger the difference of Fi (r(2) = 0.391, P < 0.01).

Effects of elastic recoil on maximal explosive power of the lower limbs / P. Zamparo, L. Sepulcri, G. Antonutto, M. Girardis, C. Capelli, P.E. Di Prampero. - In: EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY. - ISSN 0301-5548. - 75:(1997), pp. 289-297. [10.1007/s004210050163]

Effects of elastic recoil on maximal explosive power of the lower limbs

C. Capelli
Penultimo
;
1997

Abstract

The maximal explosive power during a two legs jump was measured on four competitive athletes [mean age 24 (SD 4.3) years, height 1.79 (SD 0.09) m; body mass 68.7 (SD 12.8) kg] at different starring knee angles (70, 90, 110, 130 and 150 degrees). The experiments were performed on a newly developed instrument with which both force and speed could be measured using a force platform and a wire tachometer, respectively, and on a conventional force platform. At the smallest knee angle (70 degrees) the mean power output (W radical anion in watts per kilogram) developed during the jump was found not to differ significantly between the two methods (P > 0.1). At the larger knee angles W radical anion was 18.4% (90 degrees), 34.5% (110 degrees), 47.4% (130 degrees) and 19.4% (150 degrees) higher using the conventional force platform (P < 0.05 throughout). The difference of W Radical anion between the two methods was attributed to the recovery of elastic energy due to the counter movement which immediately preceded the jump on the conventional platform, but not on the newly developed instrument. Indeed because of a mechanical arrangement which prevented the subject from moving towards the platforms, eccentric work (W-) could not be performed on the newly developed instrument; whereas Won the conventional force platform was almost negligible at 70 degrees knee angle [mean 1.7 (SD 2.3 J)] reached a maximum of 13.1 (SD 7.9)J at 130 degrees and decreased again to a mean 4.7 (SD 3.6) J for the largest angle (150 degrees). Furthermore, on the conventional force platform, the force at the onset of the positive speed phase (Fi) was an increasing function of W- (r(2) = 0.519, P < 0.001); and the difference of W Radical anion between the conventional and new instruments was larger the larger the difference of Fi (r(2) = 0.391, P < 0.01).
jumping test; maximal explosive power; elastic recoil
Settore BIOS-06/A - Fisiologia
1997
Article (author)
File in questo prodotto:
File Dimensione Formato  
Zamparo EJAP 1997.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 250.78 kB
Formato Adobe PDF
250.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1117533
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 16
  • OpenAlex ND
social impact