Using liquid-filled catheters, we recorded, in 30 anesthetized, spontaneously breathing supine rabbits, the hydraulic pressure from the parietal subpleural interstitial space (Pspl). Through a small exposed area of parietal pleura a plastic catheter (1 mm ED), with a closed and smooth tip and several holes on the last centimeter, was carefully advanced between the muscular layer and the parietal pleura, tangentially to the pleural surface to reach the submesothelial layer. Simultaneous measurements of pleural liquid pressure (Pliq) were obtained from intrapleurally placed cannulas. End-expiratory Pspl decreased (became more negative) with increasing height (LH) according to the following: Pspl (cmH2O) = -1 - 0.4 LH (cm), the corresponding equation for Pliq being Pliq (cmH2O) = -1.5 - 0.7 LH (cm). Thus at end expiration a transpleural hydraulic pressure difference (Pliq-Pspl) developed at any height, increasing from the bottom to the top of the cavity as Pliq - Pspl (cmH2O) = -0.5 - 0.3 LH (cm). The Pliq-Pspl difference increased during inspiration due to the much smaller tidal change in Pspl than in Pliq. By considering the gravity-dependent distribution of the functional hydrostatic pressure in the systemic capillaries of the pleura (Pc) and the Pspl and Pliq values integrated over the respiratory cycle we estimated that on the average, the Pc-Pspl difference is sevenfold larger than the Pspl-Pliq difference.

Gravity-dependent distribution of parietal subpleural interstitial pressure / D. Negrini, C. Capelli, M. Morini, G. Miserocchi. - In: JOURNAL OF APPLIED PHYSIOLOGY. - ISSN 8750-7587. - 63:5(1987), pp. 1912-1918. [10.1152/jappl.1987.63.5.1912]

Gravity-dependent distribution of parietal subpleural interstitial pressure

C. Capelli
Secondo
;
1987

Abstract

Using liquid-filled catheters, we recorded, in 30 anesthetized, spontaneously breathing supine rabbits, the hydraulic pressure from the parietal subpleural interstitial space (Pspl). Through a small exposed area of parietal pleura a plastic catheter (1 mm ED), with a closed and smooth tip and several holes on the last centimeter, was carefully advanced between the muscular layer and the parietal pleura, tangentially to the pleural surface to reach the submesothelial layer. Simultaneous measurements of pleural liquid pressure (Pliq) were obtained from intrapleurally placed cannulas. End-expiratory Pspl decreased (became more negative) with increasing height (LH) according to the following: Pspl (cmH2O) = -1 - 0.4 LH (cm), the corresponding equation for Pliq being Pliq (cmH2O) = -1.5 - 0.7 LH (cm). Thus at end expiration a transpleural hydraulic pressure difference (Pliq-Pspl) developed at any height, increasing from the bottom to the top of the cavity as Pliq - Pspl (cmH2O) = -0.5 - 0.3 LH (cm). The Pliq-Pspl difference increased during inspiration due to the much smaller tidal change in Pspl than in Pliq. By considering the gravity-dependent distribution of the functional hydrostatic pressure in the systemic capillaries of the pleura (Pc) and the Pspl and Pliq values integrated over the respiratory cycle we estimated that on the average, the Pc-Pspl difference is sevenfold larger than the Pspl-Pliq difference.
pleural space; pleural liquid pressure; Starling equilibrium
Settore BIOS-06/A - Fisiologia
1987
Article (author)
File in questo prodotto:
File Dimensione Formato  
Negrini_et_al-1987.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 796.01 kB
Formato Adobe PDF
796.01 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1117532
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 21
  • OpenAlex ND
social impact