Background: The use of prone position (PP) has been widespread during the COVID-19 pandemic. Whereas it has demonstrated benefits, including improved oxygenation and lung aeration, the factors influencing the response in terms of gas exchange to PP remain unclear. In particular, the association between baseline quantitative computed tomography (CT) scan results and gas exchange response to PP in invasively ventilated subjects with COVID-19 ARDS is unknown. The present study aimed to compare baseline quantitative CT results between subjects responding to PP in terms of oxygenation or CO2 clearance and those who did not. Methods: This was a single-center, retrospective observational study including critically ill, invasively ventilated subjects with COVID-19-related ARDS admitted to the ICUs of Niguarda Hospital between March 2020-November 2021. Blood gas samples were collected before and after PP. Subjects in whom the PaO2 /FIO2 increase was ≥ 20 mm Hg after PP were defined as oxygen responders. CO2 responders were defined when the ventilatory ratio (VR) decreased during PP. Automated quantitative CT analyses were performed to obtain tissue mass and density of the lungs. Results: One hundred twenty-five subjects were enrolled, of which 116 (93%) were O2 responders and 51 (41%) CO2 responders. No difference in quantitative CT characteristics and oxygen were observed between responders and non-responders (tissue mass 1,532 ± 396 g vs 1,654 ± 304 g, P = .28; density -544 ± 109 HU vs -562 ± 58 HU P = .42). Similar findings were observed when dividing the population according to CO2 response (tissue mass 1,551 ± 412 g vs 1,534 ± 377 g, P = .89; density -545 ± 123 HU vs -546 ± 94 HU, P = .99). Conclusions: Most subjects with COVID-19-related ARDS improved their oxygenation at the first pronation cycle. The study suggests that baseline quantitative CT scan data were not associated with the response to PP in oxygenation or CO2 in mechanically ventilated subjects with COVID-19-related ARDS.

Quantitative Computed Tomography and Response to Pronation in COVID-19 ARDS / F. Zadek, L. Berta, G. Zorzi, S. Ubiali, A. Bonaiti, G. Tundo, B. Brunoni, F. Marrazzo, R. Giudici, A. Rossi, F. Rizzetto, D.P. Bernasconi, A. Vanzulli, P.E. Colombo, R. Fumagalli, A. Torresin, T. Langer. - In: RESPIRATORY CARE. - ISSN 0020-1324. - 69:11(2024 Nov 01), pp. 1380-1391. [10.4187/respcare.11625]

Quantitative Computed Tomography and Response to Pronation in COVID-19 ARDS

F. Zadek
Primo
;
L. Berta
Secondo
;
G. Zorzi;A. Bonaiti;F. Marrazzo;R. Giudici;F. Rizzetto;A. Vanzulli;A. Torresin
Penultimo
;
T. Langer
Ultimo
2024

Abstract

Background: The use of prone position (PP) has been widespread during the COVID-19 pandemic. Whereas it has demonstrated benefits, including improved oxygenation and lung aeration, the factors influencing the response in terms of gas exchange to PP remain unclear. In particular, the association between baseline quantitative computed tomography (CT) scan results and gas exchange response to PP in invasively ventilated subjects with COVID-19 ARDS is unknown. The present study aimed to compare baseline quantitative CT results between subjects responding to PP in terms of oxygenation or CO2 clearance and those who did not. Methods: This was a single-center, retrospective observational study including critically ill, invasively ventilated subjects with COVID-19-related ARDS admitted to the ICUs of Niguarda Hospital between March 2020-November 2021. Blood gas samples were collected before and after PP. Subjects in whom the PaO2 /FIO2 increase was ≥ 20 mm Hg after PP were defined as oxygen responders. CO2 responders were defined when the ventilatory ratio (VR) decreased during PP. Automated quantitative CT analyses were performed to obtain tissue mass and density of the lungs. Results: One hundred twenty-five subjects were enrolled, of which 116 (93%) were O2 responders and 51 (41%) CO2 responders. No difference in quantitative CT characteristics and oxygen were observed between responders and non-responders (tissue mass 1,532 ± 396 g vs 1,654 ± 304 g, P = .28; density -544 ± 109 HU vs -562 ± 58 HU P = .42). Similar findings were observed when dividing the population according to CO2 response (tissue mass 1,551 ± 412 g vs 1,534 ± 377 g, P = .89; density -545 ± 123 HU vs -546 ± 94 HU, P = .99). Conclusions: Most subjects with COVID-19-related ARDS improved their oxygenation at the first pronation cycle. The study suggests that baseline quantitative CT scan data were not associated with the response to PP in oxygenation or CO2 in mechanically ventilated subjects with COVID-19-related ARDS.
COVID-19 ARDS; computed tomography; coronavirus SARS; lung compliance; prone position; pulmonary gas exchange; quantitative CT scan analysis; ventilation/perfusion scan
Settore MEDS-23/A - Anestesiologia
Settore MEDS-22/A - Diagnostica per immagini e radioterapia
1-nov-2024
25-ott-2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
2024_COVID_Pronation_Respiratory Care.pdf

accesso riservato

Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 2.27 MB
Formato Adobe PDF
2.27 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1116411
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact