Is there a “missing device” for respiratory personal protection? Does it exist an easy-to-use device, allowing extensive use in everyday settings by the population, maximizing tolerability and low visual and physical invasiveness protecting from a wide range of threats including airborne pathogens, hence including the particle range of fine and ultrafine particles? Looking at the recent past, in the urgency of finding ready-to-use solutions for the respiratory protection of the population during the outbreak of the SARS-CoV-2 pandemic, devices for occupational safety have been used, such as filtering face masks. These are devices intended for workers operating during work shifts in environments characterized by potential high risk, known a priori, often directly sensible; this makes wearers motivated to tolerate discomfort for a given period to face a localized risk, and safety managers determined to supervise compliance with usage specifications. Their use by general population has implied known shortcomings, such as weak compatibility with relational work and activities, low tolerability during prolonged use, low compliance with the proper use of the device, all of this lessening actual protection. The need for a new perspective has emerged, targeting effectiveness in whole daily life, rather than punctual efficacy. Nasal filters are promising candidates to protect individuals throughout the day during the most varied activities, but they lack a systematic definition as a device and as a product; it follows that the high complexity needed to reach an effective performance envelop is generally underestimated. By reviewing available literature, the present paper draws on the experience from the pandemic and infers systematic product specifications and characterization methods for a new, effective personal respiratory protection device; these specifications are compared with the stringent constraints associated with the endonasal applications and, based on air filtration state of the art, quantifies the need for technology disruption and outlining possible new development paths.
Re-inventing protection in a post-pandemic world: A new aerodynamic endonasal filtration technology / F. Broccolo, F. D'Urso, E. Imperi, P. Piscitelli, A. Miani, A. Picano. - In: ENVIRONMENTAL RESEARCH. - ISSN 0013-9351. - 249:(2024 May), pp. 118051.1-118051.10. [10.1016/j.envres.2023.118051]
Re-inventing protection in a post-pandemic world: A new aerodynamic endonasal filtration technology
A. Miani;
2024
Abstract
Is there a “missing device” for respiratory personal protection? Does it exist an easy-to-use device, allowing extensive use in everyday settings by the population, maximizing tolerability and low visual and physical invasiveness protecting from a wide range of threats including airborne pathogens, hence including the particle range of fine and ultrafine particles? Looking at the recent past, in the urgency of finding ready-to-use solutions for the respiratory protection of the population during the outbreak of the SARS-CoV-2 pandemic, devices for occupational safety have been used, such as filtering face masks. These are devices intended for workers operating during work shifts in environments characterized by potential high risk, known a priori, often directly sensible; this makes wearers motivated to tolerate discomfort for a given period to face a localized risk, and safety managers determined to supervise compliance with usage specifications. Their use by general population has implied known shortcomings, such as weak compatibility with relational work and activities, low tolerability during prolonged use, low compliance with the proper use of the device, all of this lessening actual protection. The need for a new perspective has emerged, targeting effectiveness in whole daily life, rather than punctual efficacy. Nasal filters are promising candidates to protect individuals throughout the day during the most varied activities, but they lack a systematic definition as a device and as a product; it follows that the high complexity needed to reach an effective performance envelop is generally underestimated. By reviewing available literature, the present paper draws on the experience from the pandemic and infers systematic product specifications and characterization methods for a new, effective personal respiratory protection device; these specifications are compared with the stringent constraints associated with the endonasal applications and, based on air filtration state of the art, quantifies the need for technology disruption and outlining possible new development paths.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0013935123028554-main.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
2.51 MB
Formato
Adobe PDF
|
2.51 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.