In recent years, surface magnetic resonance tomography (MRT), which is applied to the direct determination of the presence of groundwater, has been developed from underground two-dimensional to three-dimensional (3D) imaging. However, because of the influence of subsurface electrical conductivity, the magnetic resonance sounding (MRS) signal has been proved to be a complex-valued form. Moreover, the real and imaginary parts of MRS signals show different sensitivities to aquifers of different depths. In this study, a complex model of 3D MRT with separated loops configuration is introduced to provide accurate water-bearing imaging. Through simulation experiments, we demonstrate that the separated loops configuration is conducive to obtaining the imaginary part signal of MRS. Compared with a conventional model, the complex model has better 3D imaging resolution and sensitivity, especially for the deep regions. Moreover, in the case of noise interference and the presence of a multi-aquifer, the imaging results of complex inversion are reliable. As a result, this study is significant to the further development of multi-channel MRS instruments and provides a feasible method for high-precision imaging.

Surface Magnetic Resonance Tomography for Three-Dimensional Groundwater Using a Complex Model / J. Chen, Y. Yang, L. Wan, T. Lin. - In: PROGRESS IN ELECTROMAGNETICS RESEARCH C. - ISSN 1937-8718. - 105:(2020 Sep 11), pp. 101-115. [10.2528/pierc20061901]

Surface Magnetic Resonance Tomography for Three-Dimensional Groundwater Using a Complex Model

J. Chen
Primo
;
2020

Abstract

In recent years, surface magnetic resonance tomography (MRT), which is applied to the direct determination of the presence of groundwater, has been developed from underground two-dimensional to three-dimensional (3D) imaging. However, because of the influence of subsurface electrical conductivity, the magnetic resonance sounding (MRS) signal has been proved to be a complex-valued form. Moreover, the real and imaginary parts of MRS signals show different sensitivities to aquifers of different depths. In this study, a complex model of 3D MRT with separated loops configuration is introduced to provide accurate water-bearing imaging. Through simulation experiments, we demonstrate that the separated loops configuration is conducive to obtaining the imaginary part signal of MRS. Compared with a conventional model, the complex model has better 3D imaging resolution and sensitivity, especially for the deep regions. Moreover, in the case of noise interference and the presence of a multi-aquifer, the imaging results of complex inversion are reliable. As a result, this study is significant to the further development of multi-channel MRS instruments and provides a feasible method for high-precision imaging.
Settore GEOS-04/B - Geofisica applicata
11-set-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
12_Surface Magnetic Resonance Tomography for Three-Dimensional.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 856.98 kB
Formato Adobe PDF
856.98 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1115120
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact