Purpose This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard. Methods This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test. Results Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment. Conclusions CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.

Ischemic core detection threshold of computed tomography perfusion (CTP) in acute stroke / L. Asmundo, M. Zanardo, M. Cressoni, F. Ambrogi, L. Bet, F. Giatsidis, G. Di Leo, F. Sardanelli, P. Vitali. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 129:10(2024 Oct), pp. 1522-1529. [10.1007/s11547-024-01868-x]

Ischemic core detection threshold of computed tomography perfusion (CTP) in acute stroke

L. Asmundo
Primo
;
F. Ambrogi;F. Sardanelli
Penultimo
;
P. Vitali
Ultimo
2024

Abstract

Purpose This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard. Methods This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test. Results Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment. Conclusions CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.
computed tomography perfusion; diffusion-weighted magnetic resonance imaging; Ischemic stroke; ischemic core; threshold
Settore MEDS-22/A - Diagnostica per immagini e radioterapia
ott-2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
s11547-024-01868-x.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 796.29 kB
Formato Adobe PDF
796.29 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
213f0d67-403e-410a-a261-3e6e11c68995.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 796.1 kB
Formato Adobe PDF
796.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1113428
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact