Purpose This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard. Methods This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test. Results Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment. Conclusions CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.
Ischemic core detection threshold of computed tomography perfusion (CTP) in acute stroke / L. Asmundo, M. Zanardo, M. Cressoni, F. Ambrogi, L. Bet, F. Giatsidis, G. Di Leo, F. Sardanelli, P. Vitali. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 129:10(2024 Oct), pp. 1522-1529. [10.1007/s11547-024-01868-x]
Ischemic core detection threshold of computed tomography perfusion (CTP) in acute stroke
L. AsmundoPrimo
;F. Ambrogi;F. SardanelliPenultimo
;P. VitaliUltimo
2024
Abstract
Purpose This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard. Methods This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test. Results Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment. Conclusions CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.File | Dimensione | Formato | |
---|---|---|---|
s11547-024-01868-x.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
796.29 kB
Formato
Adobe PDF
|
796.29 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
213f0d67-403e-410a-a261-3e6e11c68995.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
796.1 kB
Formato
Adobe PDF
|
796.1 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.