Purpose: To assess whether a recently introduced implant placement micromotor that provides site-specific, operator independent cancellous bone density measurements can detect the presence of a cortical bone layer and measure its thickness and density. Materials and Methods: An in vitro experiment was performed on six double-layer polyurethane foam blocks mimicking the jawbone with different cortical thickness/cancellous density combinations. The densities were measured using the micromotor after either removing the cortical layer or leaving it intact, both with and without irrigation. Results: The results were compared by means of nonparametric statistical tests. Independent of irrigation, the micromotor detected the cortical layer when it was left intact and accurately estimated its thickness. The micromotor did not discriminate between blocks when they were considered separately, but it did when they were grouped into four or three classes. Conclusions: The present study suggests that the micromotor may represent a valid device to quantitatively assess bone quality and density. If the micromotor can quantitatively distinguish different cortical/cancellous bone combinations in humans, it may be a helpful tool for performing finely tuned, patient-tailored preparations of the implant seat, making tooth rehabilitation in challenging clinical conditions more predictable.

Using a bone density measuring micromotor to distinguish different cortical/cancellous combinations in vitro: a study using polyurethane foam blocks / P. Arosio, M. Sartori, F. Arosio, U. Garagiola, D.A. Di Stefano. - In: THE INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS. - ISSN 0882-2786. - 39:2(2024 Apr 24), pp. 310-318. [10.11607/jomi.10467]

Using a bone density measuring micromotor to distinguish different cortical/cancellous combinations in vitro: a study using polyurethane foam blocks

U. Garagiola
Penultimo
;
2024

Abstract

Purpose: To assess whether a recently introduced implant placement micromotor that provides site-specific, operator independent cancellous bone density measurements can detect the presence of a cortical bone layer and measure its thickness and density. Materials and Methods: An in vitro experiment was performed on six double-layer polyurethane foam blocks mimicking the jawbone with different cortical thickness/cancellous density combinations. The densities were measured using the micromotor after either removing the cortical layer or leaving it intact, both with and without irrigation. Results: The results were compared by means of nonparametric statistical tests. Independent of irrigation, the micromotor detected the cortical layer when it was left intact and accurately estimated its thickness. The micromotor did not discriminate between blocks when they were considered separately, but it did when they were grouped into four or three classes. Conclusions: The present study suggests that the micromotor may represent a valid device to quantitatively assess bone quality and density. If the micromotor can quantitatively distinguish different cortical/cancellous bone combinations in humans, it may be a helpful tool for performing finely tuned, patient-tailored preparations of the implant seat, making tooth rehabilitation in challenging clinical conditions more predictable.
cortical bone; cancellous density; insertion torque; micromotor; primary stability; implant placement
Settore MED/28 - Malattie Odontostomatologiche
Settore MEDS-16/A - Malattie odontostomatologiche
24-apr-2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
2024 Using a bone density measuring - Int J Oral Maxillofacial Implants conv.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.8 MB
Formato Adobe PDF
1.8 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1096188
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact