Objective: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). Methods: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. Results: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra-and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra-and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. Conclusion: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.
Development of a new ultrasound scoring system to evaluate glandular inflammation in Sjögren's syndrome: An OMERACT reliability exercise / A. Hocevar, G.A. Bruyn, L. Terslev, J.J. De Agustin, D. Maccarter, S. Chrysidis, P. Collado, C. Dejaco, V. Fana, G. Filippou, S. Finzel, F. Gandjbakhch, P. Hanova, D. Hammenfors, C. Hernandez-Diaz, A. Iagnocco, M.A. Mortada, N. Inanc, E. Naredo, S. Ohrndorf, N. Perko, W.A. Schmidt, G. Tamborrini, M. Tomsic, I. Chary-Valckenaere, A. Zabotti, H.I. Keen, C. Pineda, M.-. D'Agostino, S. Jousse-Joulin. - In: RHEUMATOLOGY. - ISSN 1462-0324. - 61:8(2022), pp. 3341-3350. [10.1093/rheumatology/keab876]
Development of a new ultrasound scoring system to evaluate glandular inflammation in Sjögren's syndrome: An OMERACT reliability exercise
G. Filippou;
2022
Abstract
Objective: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). Methods: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. Results: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra-and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra-and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. Conclusion: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.File | Dimensione | Formato | |
---|---|---|---|
keab876.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
895.98 kB
Formato
Adobe PDF
|
895.98 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.