Context: Surface replacement of the hip is aimed especially at active patients, and it seems to achieve optimal functional results in a short time if associated with a tailored rehabilitation protocol. Objective: To assess the functional outcome in a group of active patients after hip resurfacing. Design: Clinical measurement and controlled laboratory study in a case series. Setting: Gait-analysis laboratory. Participants: 8 patients and a control group of 10 subjects. Interventions: Patients treated with Birmingham hip-resurfacing system and a tailored rehabilitation protocol Main Outcome Measures: Clinical assessment (Harris Hip Score [HHS]) and instrumented gait analysis including muscular electromyographic assessment. Patients were assessed preoperatively and at 3 and 9 mo follow-up after surgery. Results: HHS showed a significant increase from the baseline to 3- (P =.008) and 9-month (P =.014) follow-up; 5 patients returned to sport. Gait pattern in the presented case series of patients improved substantially 3 mo postoperatively, and minimal further changes were present 9 months postoperatively. Residual abnormalities of time-distance and hip-kinematics parameters were consistent with a slow gait. A complete restoration of the muscle-activation pattern during gait was achieved. Conclusion: Hip resurfacing associated with a rehabilitation protocol based on the characteristics of the implant provides excellent clinical and functional outcome, especially for very active patients.

Functional recovery after hip resurfacing and rehabilitation / M. Benedetti, L. Berti, A. Frizziero, D. Ferrarese, S. Giannini. - In: JOURNAL OF SPORT REHABILITATION. - ISSN 1056-6716. - 21:2(2012), pp. 167-174. [10.1123/jsr.21.2.167]

Functional recovery after hip resurfacing and rehabilitation

A. Frizziero;
2012

Abstract

Context: Surface replacement of the hip is aimed especially at active patients, and it seems to achieve optimal functional results in a short time if associated with a tailored rehabilitation protocol. Objective: To assess the functional outcome in a group of active patients after hip resurfacing. Design: Clinical measurement and controlled laboratory study in a case series. Setting: Gait-analysis laboratory. Participants: 8 patients and a control group of 10 subjects. Interventions: Patients treated with Birmingham hip-resurfacing system and a tailored rehabilitation protocol Main Outcome Measures: Clinical assessment (Harris Hip Score [HHS]) and instrumented gait analysis including muscular electromyographic assessment. Patients were assessed preoperatively and at 3 and 9 mo follow-up after surgery. Results: HHS showed a significant increase from the baseline to 3- (P =.008) and 9-month (P =.014) follow-up; 5 patients returned to sport. Gait pattern in the presented case series of patients improved substantially 3 mo postoperatively, and minimal further changes were present 9 months postoperatively. Residual abnormalities of time-distance and hip-kinematics parameters were consistent with a slow gait. A complete restoration of the muscle-activation pattern during gait was achieved. Conclusion: Hip resurfacing associated with a rehabilitation protocol based on the characteristics of the implant provides excellent clinical and functional outcome, especially for very active patients.
rehabilitation; gait analysis; joint arthroplasty
Settore MED/34 - Medicina Fisica e Riabilitativa
2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
Benedetti Mc Minn.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 442.99 kB
Formato Adobe PDF
442.99 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1083502
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
  • OpenAlex ND
social impact