Aim: Obstructive Sleep Apnoea Syndrome (OSAS) shows apnoea or hypopnea due to upper airways stenosis during sleep with its typical symptoms including snoring during sleep and excessive daytime sleepiness. Cone Beam Computed Tomography (CBCT) is useful to reach an accurate 3D volumetric analysis of upper airways. The Oral Appliances (OA) are considered to be an effective treatment for Obstructive Sleep Apnea Syndrome (OSAS). The aim is to detect morphological changes in upper airways using CBCT before and after oral appliance therapy. Material and Methods: The study included 50 patients (26 males and 24 females). They were diagnosed with OSAS using polysomnography (PSG). Some criteria has been applied to diagnose OSAS: an apnoea-hypopnoea index (AHI) of >5 per hour during sleep and pathological daytime sleepiness. The therapeutic effect of oral appliance was evaluated by using PSG and when it showed an AHI of <10 or a decrease of >50%. Two types of OA were applied: the Mandibular Advancement Device and Twin Block Appliance. These enlarged the upper airways by holding the mandible forward, at the 60-70% of the maximum mandible advancement and at the minimum vertical position. A CBCT was performed in all the patients. Results and Conclusion: The mean upper airways’ 3D volumetric reconstructions increased significantly during the presence of OA versus the absence of OA (p<0.01). AHI diminished significantly during the presence of OA (p<0.01). Oral therapy is effective for treating mild and moderate OSA. the advantage of a 3D evaluation of the upper airway during OA therapy is the accurate visual confirmation of morphological changes in each region of the upper airway and it could increase the compliance and motivation of the patients for the treatment. OSAS treatment methods included surgery, nasal continuous positive airway pressure (NCPAP), weight reduction, drug therapy and, in the mild and moderate OSA, the use of oral appliances. CBCT is useful to detect morphological changes od upper airways, by a 3D evaluation analysis during oral devices’ use. The management of the obstructive sleep apnoea syndrome could be challenging. The treatment recommendations should be proposed by a multidisciplinary approach, that involves different specialists: otorhinolaryngologists surgeons, neurologists, sleep doctors and dentists.

Upper airways 3D volumetric analysis before and after oral appliance therapy in obstructive sleep apnoea / U. Garagiola, E. del Rosso, C. Cressoni, L. Cigni, F. Spadari. ((Intervento presentato al convegno SIDO-AIDOR International Spring Meeting tenutosi a Napoli nel 2021.

Upper airways 3D volumetric analysis before and after oral appliance therapy in obstructive sleep apnoea

U. Garagiola
Primo
;
E. del Rosso
Secondo
;
L. Cigni
Penultimo
;
F. Spadari
Ultimo
2021

Abstract

Aim: Obstructive Sleep Apnoea Syndrome (OSAS) shows apnoea or hypopnea due to upper airways stenosis during sleep with its typical symptoms including snoring during sleep and excessive daytime sleepiness. Cone Beam Computed Tomography (CBCT) is useful to reach an accurate 3D volumetric analysis of upper airways. The Oral Appliances (OA) are considered to be an effective treatment for Obstructive Sleep Apnea Syndrome (OSAS). The aim is to detect morphological changes in upper airways using CBCT before and after oral appliance therapy. Material and Methods: The study included 50 patients (26 males and 24 females). They were diagnosed with OSAS using polysomnography (PSG). Some criteria has been applied to diagnose OSAS: an apnoea-hypopnoea index (AHI) of >5 per hour during sleep and pathological daytime sleepiness. The therapeutic effect of oral appliance was evaluated by using PSG and when it showed an AHI of <10 or a decrease of >50%. Two types of OA were applied: the Mandibular Advancement Device and Twin Block Appliance. These enlarged the upper airways by holding the mandible forward, at the 60-70% of the maximum mandible advancement and at the minimum vertical position. A CBCT was performed in all the patients. Results and Conclusion: The mean upper airways’ 3D volumetric reconstructions increased significantly during the presence of OA versus the absence of OA (p<0.01). AHI diminished significantly during the presence of OA (p<0.01). Oral therapy is effective for treating mild and moderate OSA. the advantage of a 3D evaluation of the upper airway during OA therapy is the accurate visual confirmation of morphological changes in each region of the upper airway and it could increase the compliance and motivation of the patients for the treatment. OSAS treatment methods included surgery, nasal continuous positive airway pressure (NCPAP), weight reduction, drug therapy and, in the mild and moderate OSA, the use of oral appliances. CBCT is useful to detect morphological changes od upper airways, by a 3D evaluation analysis during oral devices’ use. The management of the obstructive sleep apnoea syndrome could be challenging. The treatment recommendations should be proposed by a multidisciplinary approach, that involves different specialists: otorhinolaryngologists surgeons, neurologists, sleep doctors and dentists.
lug-2021
Settore MED/28 - Malattie Odontostomatologiche
Società Italiana di Ortodonzia (SIDO)
Accademia Italiana di Ortodonzia (AIDOR)
https://www.sido.it/wp-content/uploads/2022/03/programma_sala_15062021.pdf
Upper airways 3D volumetric analysis before and after oral appliance therapy in obstructive sleep apnoea / U. Garagiola, E. del Rosso, C. Cressoni, L. Cigni, F. Spadari. ((Intervento presentato al convegno SIDO-AIDOR International Spring Meeting tenutosi a Napoli nel 2021.
Conference Object
File in questo prodotto:
File Dimensione Formato  
2021 Upper airways 3D -Sido Spring .pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 302.31 kB
Formato Adobe PDF
302.31 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1073308
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact