Purpose: Cadiax 2 compact is a computerized axiograph capable of producing axiograms of three-dimensional mandibular movements. This technology is considered accurate and precise to measure the horizontal condylar inclination (HCI) and the Bennett angle and allows the processing of curve data through software and the calculation of significant numerical! parameters for the formulation of observations pf clinical interest. In this preliminary study, measurements were carried put in non-dysfunctional patients applying for orthodontic treatment in order to verify the variability of the curves and intercept any temporomandibular dysfunction before treatment. Materials and Methods: 19 patients applying for orthodontic treatment aged between 13 and 24 were recruited at the Orthodontic ward of, IRCCS Ca' Granda Policlinico Hospital Foundation of Milano. Patients with a history of systemic arthropathies or arthritis, postural! pathologies, history of facial trauma, previous orthognathic treatments or prosthetic rehabilitations, history of pain or temporomandibular dysfunction were excluded. Were also excluded patients who complained pain on pressure at physical examination, joint noises and maximum opening <40 mm. The CADIAX compact 2 system was used for arbitrary recordings. This means that the registration of the movement of the mandibular joint was made on one point of the axis anatomically identified hinge. The reference coordinates of the system originate from the central point between the condyles, where the hinge axis, in the zero (centric) position, intersects with the median-sagittal plane. A kinematic face bow (Condylograph) was used for the recordings. All the recordings in their entirety, including the preparation phases and the determination of the hinge axis, were performed by the same operator. A complete axiographic exam was performed [3] but a selection of non-guided open/close curves was tracked for the analysis. Each record therefore included: 1) Electronically recorded jaw movement tracks; 2} Measurement of the condylographic position (CPM); 3) X / Y / Z coordinates of the tips of the cusps of the teeth of the mandible. The registration data was exported to GAMMA Dental Software and subsequently processed with CADIAX Analyzer. For each curve the parameter of symmetry and harmony of movement was noted, defined as the linearity as the sign of the path and allows us to classify the path as: excellent, good or poor. Results and Conclusions: An average value of movement harmony of 61.623°/mm ± 15.587°/mm and of symmetry 115.683°/mm ± 27.149°/mm was reported. Although this investigation was performed in patients who were not frankly dysfunctional, and our data show sub-clinical alterations of the condylar dynamics. In conclusion, hon-guided open/close curves were selected in representation of habitual function and our results proved for a poorer quality than expected on average, Results from this preliminary study should be verified in a larger sample, however it is reasonable to state that, especially in adolescents and young adults, the condylographic examination could intercept risk conditions for temporomandibular dysfunction in the pretreatment phase and allows further diagnostic investigations in the gnathological field.

Condylographic evaluation in patients applying for orthognathodontic treatment: study of the quality of movement in opening and closing in non-dysfunctional patients / S. Marino, G. Colangelo, F. Pulicari, U. Garagiola, F. Spadari. ((Intervento presentato al 52 SIDO; 18 AIDOR. convegno SIDO – AIDOR International Congress tenutosi a Firenze nel 2021.

Condylographic evaluation in patients applying for orthognathodontic treatment: study of the quality of movement in opening and closing in non-dysfunctional patients

G. Colangelo
Secondo
;
U. Garagiola
Penultimo
;
F. Spadari
Ultimo
2021

Abstract

Purpose: Cadiax 2 compact is a computerized axiograph capable of producing axiograms of three-dimensional mandibular movements. This technology is considered accurate and precise to measure the horizontal condylar inclination (HCI) and the Bennett angle and allows the processing of curve data through software and the calculation of significant numerical! parameters for the formulation of observations pf clinical interest. In this preliminary study, measurements were carried put in non-dysfunctional patients applying for orthodontic treatment in order to verify the variability of the curves and intercept any temporomandibular dysfunction before treatment. Materials and Methods: 19 patients applying for orthodontic treatment aged between 13 and 24 were recruited at the Orthodontic ward of, IRCCS Ca' Granda Policlinico Hospital Foundation of Milano. Patients with a history of systemic arthropathies or arthritis, postural! pathologies, history of facial trauma, previous orthognathic treatments or prosthetic rehabilitations, history of pain or temporomandibular dysfunction were excluded. Were also excluded patients who complained pain on pressure at physical examination, joint noises and maximum opening <40 mm. The CADIAX compact 2 system was used for arbitrary recordings. This means that the registration of the movement of the mandibular joint was made on one point of the axis anatomically identified hinge. The reference coordinates of the system originate from the central point between the condyles, where the hinge axis, in the zero (centric) position, intersects with the median-sagittal plane. A kinematic face bow (Condylograph) was used for the recordings. All the recordings in their entirety, including the preparation phases and the determination of the hinge axis, were performed by the same operator. A complete axiographic exam was performed [3] but a selection of non-guided open/close curves was tracked for the analysis. Each record therefore included: 1) Electronically recorded jaw movement tracks; 2} Measurement of the condylographic position (CPM); 3) X / Y / Z coordinates of the tips of the cusps of the teeth of the mandible. The registration data was exported to GAMMA Dental Software and subsequently processed with CADIAX Analyzer. For each curve the parameter of symmetry and harmony of movement was noted, defined as the linearity as the sign of the path and allows us to classify the path as: excellent, good or poor. Results and Conclusions: An average value of movement harmony of 61.623°/mm ± 15.587°/mm and of symmetry 115.683°/mm ± 27.149°/mm was reported. Although this investigation was performed in patients who were not frankly dysfunctional, and our data show sub-clinical alterations of the condylar dynamics. In conclusion, hon-guided open/close curves were selected in representation of habitual function and our results proved for a poorer quality than expected on average, Results from this preliminary study should be verified in a larger sample, however it is reasonable to state that, especially in adolescents and young adults, the condylographic examination could intercept risk conditions for temporomandibular dysfunction in the pretreatment phase and allows further diagnostic investigations in the gnathological field.
nov-2021
Settore MED/28 - Malattie Odontostomatologiche
Società Italiana di Ortodonzia (SIDO)
Accademia Italiana di Ortodonzia (AIDOR)
https://www.sido.it/wp-content/uploads/2022/03/Programma_sala_291021.pdf
Condylographic evaluation in patients applying for orthognathodontic treatment: study of the quality of movement in opening and closing in non-dysfunctional patients / S. Marino, G. Colangelo, F. Pulicari, U. Garagiola, F. Spadari. ((Intervento presentato al 52 SIDO; 18 AIDOR. convegno SIDO – AIDOR International Congress tenutosi a Firenze nel 2021.
Conference Object
File in questo prodotto:
File Dimensione Formato  
2021 Condylographic evaluation in patients - SIDO-AIDOR.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 216.65 kB
Formato Adobe PDF
216.65 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1072249
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact