We developed a scanner for micro computed tomography dedicated to the breast (BµCT) with a high resolution flat-panel detector and a microfocus X-ray tube. We evaluated the system spatial resolution via the 3D modulation transfer function (MTF). In addition to conventional absorption-based X-ray imaging, such a prototype showed capabilities for propagation-based phase-contrast and related edge enhancement effects in 3D imaging. The system limiting spatial resolution is 6.2 mm−1 (MTF at 10%) in the vertical direction and 3.8 mm−1 in the radial direction, values which compare favorably with the spatial resolution reached by mini focus breast CT scanners of other groups. The BµCT scanner was able to detect both microcalcification clusters and masses in an anthropomorphic breast phantom at a dose comparable to that of two-view mammography. The use of a breast holder is proposed in order to have 1–2 min long scan times without breast motion artifacts.

Cone-beam micro computed tomography dedicated to the breast / A. Sarno, G. Mettivier, F. Di Lillo, M. Cesarelli, P. Bifulco, P. Russo. - In: MEDICAL ENGINEERING & PHYSICS. - ISSN 1350-4533. - 38:12(2016), pp. 1449-1457. [10.1016/j.medengphy.2016.09.012]

Cone-beam micro computed tomography dedicated to the breast

A. Sarno
Primo
;
2016

Abstract

We developed a scanner for micro computed tomography dedicated to the breast (BµCT) with a high resolution flat-panel detector and a microfocus X-ray tube. We evaluated the system spatial resolution via the 3D modulation transfer function (MTF). In addition to conventional absorption-based X-ray imaging, such a prototype showed capabilities for propagation-based phase-contrast and related edge enhancement effects in 3D imaging. The system limiting spatial resolution is 6.2 mm−1 (MTF at 10%) in the vertical direction and 3.8 mm−1 in the radial direction, values which compare favorably with the spatial resolution reached by mini focus breast CT scanners of other groups. The BµCT scanner was able to detect both microcalcification clusters and masses in an anthropomorphic breast phantom at a dose comparable to that of two-view mammography. The use of a breast holder is proposed in order to have 1–2 min long scan times without breast motion artifacts.
Breast cancer; Diagnosis; Micro computed tomography; MTF; Phase contrast
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1350453316302120-main.pdf

accesso riservato

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 2.38 MB
Formato Adobe PDF
2.38 MB Adobe PDF   Visualizza/Apri   Richiedi una copia