BackgroundIn primary antibody deficiencies (PADs), pulmonary complications are the main cause of morbidity, despite immunoglobulin substitutive therapy, antibiotic treatment of exacerbations, and respiratory physiotherapy. Current Italian recommendations for surveillance of PADs respiratory complications include an annual assessment of spirometry and execution of chest high-resolution computed tomography (HRCT) every 4 years. ObjectiveThis study aimed to evaluate the effectiveness of the lung clearance index (LCI) as an early marker of lung damage in patients with PADs. LCI is measured by multiple breath washout (MBW), a non-invasive and highly specific test widely used in patients with cystic fibrosis (CF). MethodsPediatric patients with PADs (n = 17, 10 male, 7 female, and age range 5-15 years) underwent baseline assessment of lung involvement with chest HRCT, spirometry, and multiple breath nitrogen washout. Among them, 13 patients were followed up to repeat HRCT after 4 years, while performing pulmonary function tests annually. Their baseline and follow-up LCI and forced expiratory volume at 1 s (FEV1) values were compared, taking HRCT as the gold standard, using logistic regression analysis. ResultsLung clearance index [odds ratio (OR) 2.3 (confidence interval (CI) 0.1-52) at baseline, OR 3.9 (CI 0.2-191) at follow-up] has a stronger discriminating power between altered and normal HRCT rather than FEV1 [OR 0.6 (CI 0.2-2) at baseline, OR 1.6 (CI 0.1-13.6) at follow-up]. ConclusionWithin the context of a limited sample size, LCI seems to be more predictive of HRCT alterations than FEV1 and more sensitive than HRCT in detecting non-uniform ventilation in the absence of bronchiectasis. A study of a larger cohort of pediatric patients followed longitudinally in adulthood is needed to challenge these findings.

Multiple Breath Washout for Early Assessment of Pulmonary Complications in Patients With Primary Antibody Deficiencies: An Observational Study in Pediatric Age / T. Secchi, L.A. Baselli, M.C. Russo, I.M. Borzani, F. Carta, M.A. Lopopolo, M. Foà, A. La Vecchia, C. Agostoni, M. Agosti, R.M. Dellepiane. - In: FRONTIERS IN PEDIATRICS. - ISSN 2296-2360. - 10:(2022 May 17), pp. 773751.1-773751.10. [10.3389/fped.2022.773751]

Multiple Breath Washout for Early Assessment of Pulmonary Complications in Patients With Primary Antibody Deficiencies: An Observational Study in Pediatric Age

A. La Vecchia;C. Agostoni;
2022

Abstract

BackgroundIn primary antibody deficiencies (PADs), pulmonary complications are the main cause of morbidity, despite immunoglobulin substitutive therapy, antibiotic treatment of exacerbations, and respiratory physiotherapy. Current Italian recommendations for surveillance of PADs respiratory complications include an annual assessment of spirometry and execution of chest high-resolution computed tomography (HRCT) every 4 years. ObjectiveThis study aimed to evaluate the effectiveness of the lung clearance index (LCI) as an early marker of lung damage in patients with PADs. LCI is measured by multiple breath washout (MBW), a non-invasive and highly specific test widely used in patients with cystic fibrosis (CF). MethodsPediatric patients with PADs (n = 17, 10 male, 7 female, and age range 5-15 years) underwent baseline assessment of lung involvement with chest HRCT, spirometry, and multiple breath nitrogen washout. Among them, 13 patients were followed up to repeat HRCT after 4 years, while performing pulmonary function tests annually. Their baseline and follow-up LCI and forced expiratory volume at 1 s (FEV1) values were compared, taking HRCT as the gold standard, using logistic regression analysis. ResultsLung clearance index [odds ratio (OR) 2.3 (confidence interval (CI) 0.1-52) at baseline, OR 3.9 (CI 0.2-191) at follow-up] has a stronger discriminating power between altered and normal HRCT rather than FEV1 [OR 0.6 (CI 0.2-2) at baseline, OR 1.6 (CI 0.1-13.6) at follow-up]. ConclusionWithin the context of a limited sample size, LCI seems to be more predictive of HRCT alterations than FEV1 and more sensitive than HRCT in detecting non-uniform ventilation in the absence of bronchiectasis. A study of a larger cohort of pediatric patients followed longitudinally in adulthood is needed to challenge these findings.
high resolution computed tomography; human inborn errors of immunity; lung clearance index; multiple breath washout; primary antibody deficiencies; pulmonary complications; respiratory function; spirometry
Settore MED/38 - Pediatria Generale e Specialistica
17-mag-2022
Article (author)
File in questo prodotto:
File Dimensione Formato  
fped-10-773751.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.84 MB
Formato Adobe PDF
1.84 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1060208
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact