PurposeThe Dynamic Imaging Grade of Swallowing Toxicity (DIGEST) is a scale to quantify the severity of pharyngeal dysphagia in head and neck cancer (HNC) patients. This study (1) described the training process of the observers for DIGEST in fiberoptic endoscopic evaluation of swallowing (FEES), (2) determined observer agreement on the DIGEST in FEES, (3) explored the effect of bolus consistency on observer agreement, and 4) explored criterion validity of the DIGEST in FEES.MethodsTwenty-seven dysphagic HNC patients were enrolled. Two observers completed a training program for DIGEST in FEES. Observer agreement on the Penetration-Aspiration Scale (PAS), percentage of pharyngeal residue (PPR), and DIGEST grades was determined using linearly weighted Cohen's kappa coefficient (kappa).ResultsDue to insufficient observer agreement after the first measurement attempt, additional training was organized using an elaborated manual with descriptions of the visuoperceptual variables, thereby improving observer agreement. Intraobserver agreement was almost perfect on the PAS (kappa = 0.86-0.88) and PPR (kappa = 0.84-0.86). Interobserver agreement was substantial on the PAS (kappa = 0.78), almost perfect on the PPR (kappa = 0.82), substantial on the safety grade (kappa = 0.64), almost perfect on the efficiency grade (kappa = 0.85), and substantial on the summary grade (kappa = 0.71). Bolus consistency had an effect on observer agreement. A significant correlation was found between DIGEST efficiency grade and EAT-10.ConclusionThe DIGEST showed to be a reproducible measurement for FEES in terms of observer agreement. However, agreement between novice observers on the DIGEST was only reached after specific observer-tailored training. Observer agreement should be analyzed by taking bolus consistency into account during training, as this might affect the interpretation of the outcome. A manual with well-defined descriptions can optimize the reproducibility of DIGEST measurements.
Intra and interobserver agreement of the Dynamic Imaging Grade of Swallowing Toxicity Scale (DIGEST) in fiberoptic endoscopic evaluation of swallowing (FEES): the importance of observer-tailored training / S.R. Simon, M.W.M. Wieland, C. Hendriks, W. Pilz, A. Schindler, B. Winkens, L.W.J. Baijens. - In: EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY AND HEAD & NECK. - ISSN 1434-4726. - 280:6(2023 Jun), pp. 2865-2876. [10.1007/s00405-023-07840-1]
Intra and interobserver agreement of the Dynamic Imaging Grade of Swallowing Toxicity Scale (DIGEST) in fiberoptic endoscopic evaluation of swallowing (FEES): the importance of observer-tailored training
A. Schindler;
2023
Abstract
PurposeThe Dynamic Imaging Grade of Swallowing Toxicity (DIGEST) is a scale to quantify the severity of pharyngeal dysphagia in head and neck cancer (HNC) patients. This study (1) described the training process of the observers for DIGEST in fiberoptic endoscopic evaluation of swallowing (FEES), (2) determined observer agreement on the DIGEST in FEES, (3) explored the effect of bolus consistency on observer agreement, and 4) explored criterion validity of the DIGEST in FEES.MethodsTwenty-seven dysphagic HNC patients were enrolled. Two observers completed a training program for DIGEST in FEES. Observer agreement on the Penetration-Aspiration Scale (PAS), percentage of pharyngeal residue (PPR), and DIGEST grades was determined using linearly weighted Cohen's kappa coefficient (kappa).ResultsDue to insufficient observer agreement after the first measurement attempt, additional training was organized using an elaborated manual with descriptions of the visuoperceptual variables, thereby improving observer agreement. Intraobserver agreement was almost perfect on the PAS (kappa = 0.86-0.88) and PPR (kappa = 0.84-0.86). Interobserver agreement was substantial on the PAS (kappa = 0.78), almost perfect on the PPR (kappa = 0.82), substantial on the safety grade (kappa = 0.64), almost perfect on the efficiency grade (kappa = 0.85), and substantial on the summary grade (kappa = 0.71). Bolus consistency had an effect on observer agreement. A significant correlation was found between DIGEST efficiency grade and EAT-10.ConclusionThe DIGEST showed to be a reproducible measurement for FEES in terms of observer agreement. However, agreement between novice observers on the DIGEST was only reached after specific observer-tailored training. Observer agreement should be analyzed by taking bolus consistency into account during training, as this might affect the interpretation of the outcome. A manual with well-defined descriptions can optimize the reproducibility of DIGEST measurements.File | Dimensione | Formato | |
---|---|---|---|
405_2023_Article_7840.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
481.51 kB
Formato
Adobe PDF
|
481.51 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.