A new ionization method, named surface-activated chemical ionization (SACI), was employed for the analysis of five amphetamines (3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDE), amphetamine and methamphetamine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) using the same instrument, clearly showing that SACI is the most sensitive of the three. The limit of detection and linearity range for SACI were compared with those obtained using APCI and ESI, showing that the new SACI approach provides the best results for both criteria. SACI was used to analyze MDA, MDMA MDE, amphetamine and methamphetamine in four urine samples, and the quantitation results are compared with those achieved using ESI.

Surface-activated chemical ionization ion trap mass spectrometry in the analysis of amphetamines in diluted urine samples / S. Cristoni, L. Rossi Bernardi, P.Gerthoux, E. Gonella , P. Mocarelli. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - 18:16(2004), pp. 1847-1855.

Surface-activated chemical ionization ion trap mass spectrometry in the analysis of amphetamines in diluted urine samples

L. Rossi Bernardi;
2004

Abstract

A new ionization method, named surface-activated chemical ionization (SACI), was employed for the analysis of five amphetamines (3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDE), amphetamine and methamphetamine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) using the same instrument, clearly showing that SACI is the most sensitive of the three. The limit of detection and linearity range for SACI were compared with those obtained using APCI and ESI, showing that the new SACI approach provides the best results for both criteria. SACI was used to analyze MDA, MDMA MDE, amphetamine and methamphetamine in four urine samples, and the quantitation results are compared with those achieved using ESI.
English
Amphetamines Central Nervous System Stimulants Ions
Settore BIO/10 - Biochimica
Articolo
Sì, ma tipo non specificato
2004
Wiley
18
16
1847
1855
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Surface-activated chemical ionization ion trap mass spectrometry in the analysis of amphetamines in diluted urine samples / S. Cristoni, L. Rossi Bernardi, P.Gerthoux, E. Gonella , P. Mocarelli. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - 18:16(2004), pp. 1847-1855.
none
Prodotti della ricerca::01 - Articolo su periodico
5
262
Article (author)
si
S. Cristoni, L. Rossi Bernardi, P.Gerthoux, E. Gonella , P. Mocarelli
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/10428
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 21
social impact