Aim: To compare and evaluate the sealing ability of four different commercially available sealers to provide seal against the dye penetration test using a stereomicroscope-an in-vitro study. Material/method: 80 extracted single rooted mandibular premolar with single canal were used in this study. The samples were divided in 4 groups (20 in each) based on sealer. Group I (Diaproseal), Group II (apexit Plus), Group III (MTA Fillapex) and Group IV (Bio-C). The samples were analyzed using a stereomicroscope and data analysis was done with one-way Anova And post hoc Tukey's test. Result: The mean dye penetration score was 1.2400 ± 0.778 mm for Group I. 2.6000 ± 0.897 mm for Group II, 4.2000 ± 0.923 mm for Group III and 4.225 ± 2.055 mm for Group IV. One-way Anova analysis shows that intergroup comparison was statistically significant between the four groups. The post hoc Tukey's test reveals that the difference was statistically non-significant between group III and group IV. Conclusion: It was concluded that between the four groups the Group I (Diaproseal) showed the least dye penetration followed by Group II (Apexit Pus), Group III (MTA Fillapex) and then Group IV (Bio-C), where there was no significant difference between the Group III (MTA Fillapex) and Group IV (Bio-C).
Stereomicroscopic evaluation of sealing ability of four different root canal sealers: an in-vitro study / S. Sah, P. Mangat, A. Kumar, N. Sah, G.C. Shivakumar, M. Di Blasio, G. Cervino, G. Minervini. - In: BMC ORAL HEALTH. - ISSN 1472-6831. - 24:1(2024 Feb 20), pp. 258.1-258.8. [10.1186/s12903-024-03913-7]
Stereomicroscopic evaluation of sealing ability of four different root canal sealers: an in-vitro study
M. Di Blasio
;
2024
Abstract
Aim: To compare and evaluate the sealing ability of four different commercially available sealers to provide seal against the dye penetration test using a stereomicroscope-an in-vitro study. Material/method: 80 extracted single rooted mandibular premolar with single canal were used in this study. The samples were divided in 4 groups (20 in each) based on sealer. Group I (Diaproseal), Group II (apexit Plus), Group III (MTA Fillapex) and Group IV (Bio-C). The samples were analyzed using a stereomicroscope and data analysis was done with one-way Anova And post hoc Tukey's test. Result: The mean dye penetration score was 1.2400 ± 0.778 mm for Group I. 2.6000 ± 0.897 mm for Group II, 4.2000 ± 0.923 mm for Group III and 4.225 ± 2.055 mm for Group IV. One-way Anova analysis shows that intergroup comparison was statistically significant between the four groups. The post hoc Tukey's test reveals that the difference was statistically non-significant between group III and group IV. Conclusion: It was concluded that between the four groups the Group I (Diaproseal) showed the least dye penetration followed by Group II (Apexit Pus), Group III (MTA Fillapex) and then Group IV (Bio-C), where there was no significant difference between the Group III (MTA Fillapex) and Group IV (Bio-C).File | Dimensione | Formato | |
---|---|---|---|
Stereomicroscopic-evaluation-of-sealing-ability-of-four-different-root-canal-sealers-an-invitro-studyBMC-Oral-Health (1).pdf
accesso aperto
Descrizione: Research
Tipologia:
Publisher's version/PDF
Dimensione
1.48 MB
Formato
Adobe PDF
|
1.48 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.