Background: Some of the noise-intensive processes in dental laboratories include the finishing of crowns, bridges, and removable partial dentures; blowing out workpieces with steam and compressed air; and deflating casting rings. High sound pressure levels are also present in dental vibrators, polishing equipment, and sandblasters. The aim of this study was to Evaluation of the effect of noise production in dental technology laboratory on dental technician hearing capacity. Methods: For this cross-sectional study, a total of 120 dental technicians were chosen. Otoscopic evaluation and the Weber test were used to establish if they had sensorineural or transmission hearing loss at 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz, respectively. Then an OAER (objective auditory evoked response) and PTA (clinical aurimeter) test were administered (Neurosoft, Russia). The whole procedure was carried out by an audiologist and an ENT specialist. Results: The PTA results showed that the patient had mild hearing impairment overall, with the loss being more severe in the left ear than in the right. The OAE test results revealed that in-ear of the left side, 84.5% of subjects passed and 15.5% of subjects struggled and were referred to an ear specialist, whereas in the right ear, 82.7% of subjects passed and 17.3% struggled and were referred to an ear specialist. According to this study, in a right-handed study participant, the ear on the left side is more vulnerable than the right side. Differences in the mean hearing threshold at 4000 and 6000 Hz in the left ear were statistically significant in the groups of workers with eleven to fifteen years of practical experience and twenty-one to twenty-five years of practical experience, respectively (Minervini, et al. J Clin Med 12:2652, 2023). Conclusions: A statistically meaningful threshold shift from 4000 to 6000 Hz is observed as the working experience grows, and this is suggestive of sensorineural hearing impairment brought on by the noisy dental environment.

Assessment of hearing performance of dental technicians due to the professional noise exposure / S.K. Vaddamanu, F.H. Alhamoudi, R.I.H. Binduhayyim, A.H. Aljameel, M.A.M. Alwadi, M. Di Blasio, M. Cicciù, G. Minervini. - In: BMC ORAL HEALTH. - ISSN 1472-6831. - 23:1(2023 Sep 22), pp. 685.1-685.10. [10.1186/s12903-023-03392-2]

Assessment of hearing performance of dental technicians due to the professional noise exposure

M. Di Blasio
;
2023

Abstract

Background: Some of the noise-intensive processes in dental laboratories include the finishing of crowns, bridges, and removable partial dentures; blowing out workpieces with steam and compressed air; and deflating casting rings. High sound pressure levels are also present in dental vibrators, polishing equipment, and sandblasters. The aim of this study was to Evaluation of the effect of noise production in dental technology laboratory on dental technician hearing capacity. Methods: For this cross-sectional study, a total of 120 dental technicians were chosen. Otoscopic evaluation and the Weber test were used to establish if they had sensorineural or transmission hearing loss at 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz, respectively. Then an OAER (objective auditory evoked response) and PTA (clinical aurimeter) test were administered (Neurosoft, Russia). The whole procedure was carried out by an audiologist and an ENT specialist. Results: The PTA results showed that the patient had mild hearing impairment overall, with the loss being more severe in the left ear than in the right. The OAE test results revealed that in-ear of the left side, 84.5% of subjects passed and 15.5% of subjects struggled and were referred to an ear specialist, whereas in the right ear, 82.7% of subjects passed and 17.3% struggled and were referred to an ear specialist. According to this study, in a right-handed study participant, the ear on the left side is more vulnerable than the right side. Differences in the mean hearing threshold at 4000 and 6000 Hz in the left ear were statistically significant in the groups of workers with eleven to fifteen years of practical experience and twenty-one to twenty-five years of practical experience, respectively (Minervini, et al. J Clin Med 12:2652, 2023). Conclusions: A statistically meaningful threshold shift from 4000 to 6000 Hz is observed as the working experience grows, and this is suggestive of sensorineural hearing impairment brought on by the noisy dental environment.
Dental laboratory; Dental technicians; Hearing capacity; Noise;
Settore MED/28 - Malattie Odontostomatologiche
22-set-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
Assessment-of-hearing-performance-of-dental-technicians-due-to-the-professional-noise-exposureBMC-Oral-Health (1).pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1041729
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact