This study aimed at predicting the filtration surgery (FS) outcome using a machine learning (ML) approach. 102 glaucomatous patients undergoing FS were enrolled and underwent ocular surface clinical tests (OSCTs), determination of surgical site-related biometric parameters (SSPs) and conjunctival vascularization. Break-up-time, Schirmer test I, corneal fluorescein staining, Meibomian gland expressibility; conjunctival hyperemia, upper bulbar conjunctiva area of exposure, limbus to superior eyelid distance; and conjunctival epithelial and stromal (CET, CST) thickness and reflectivity (ECR, SCR) at AS-OCT were considered. Successful FS required a 30% baseline intraocular pressure reduction, with values ≤ 18 mmHg with or without medications. The classification tree (CT) was the ML algorithm used to analyze data. At the twelfth month, FS was successful in 60.8% of cases, whereas failed in 39.2%. At the variable importance ranking, CST and SCR were the predictors with the greater relative importance to the CART tree construction, followed by age. CET and ECR showed less relative importance, whereas OSCTs and SSPs were not important features. Within the CT, CST turned out the most important variable for discriminating success from failure, followed by SCR and age, with cut-off values of 75 µm, 169 on gray scale, and 62 years, respectively. The ROC curve for the classifier showed an AUC of 0.784 (0.692-0.860). In this ML approach, CT analysis found that conjunctival stroma thickness and reflectivity, along with age, can predict the FS outcome with good accuracy. A pre-operative thick and hyper-reflective stroma, and a younger age increase the risk of FS failure.
A machine learning approach to predict the glaucoma filtration surgery outcome / L. Agnifili, M. Figus, A. Porreca, L. Brescia, M. Sacchi, G. Covello, C. Posarelli, M. Di Nicola, R. Mastropasqua, P. Nucci, L. Mastropasqua. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - 13:1(2023 Oct 24), pp. 18157.1-18157.9. [10.1038/s41598-023-44659-6]
A machine learning approach to predict the glaucoma filtration surgery outcome
P. NucciPenultimo
;
2023
Abstract
This study aimed at predicting the filtration surgery (FS) outcome using a machine learning (ML) approach. 102 glaucomatous patients undergoing FS were enrolled and underwent ocular surface clinical tests (OSCTs), determination of surgical site-related biometric parameters (SSPs) and conjunctival vascularization. Break-up-time, Schirmer test I, corneal fluorescein staining, Meibomian gland expressibility; conjunctival hyperemia, upper bulbar conjunctiva area of exposure, limbus to superior eyelid distance; and conjunctival epithelial and stromal (CET, CST) thickness and reflectivity (ECR, SCR) at AS-OCT were considered. Successful FS required a 30% baseline intraocular pressure reduction, with values ≤ 18 mmHg with or without medications. The classification tree (CT) was the ML algorithm used to analyze data. At the twelfth month, FS was successful in 60.8% of cases, whereas failed in 39.2%. At the variable importance ranking, CST and SCR were the predictors with the greater relative importance to the CART tree construction, followed by age. CET and ECR showed less relative importance, whereas OSCTs and SSPs were not important features. Within the CT, CST turned out the most important variable for discriminating success from failure, followed by SCR and age, with cut-off values of 75 µm, 169 on gray scale, and 62 years, respectively. The ROC curve for the classifier showed an AUC of 0.784 (0.692-0.860). In this ML approach, CT analysis found that conjunctival stroma thickness and reflectivity, along with age, can predict the FS outcome with good accuracy. A pre-operative thick and hyper-reflective stroma, and a younger age increase the risk of FS failure.File | Dimensione | Formato | |
---|---|---|---|
A machine learning approach.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
1.56 MB
Formato
Adobe PDF
|
1.56 MB | Adobe PDF | Visualizza/Apri |