Background and aims: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. Methods: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. Results: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. Conclusions: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.

Implantable cardioverter defibrillator use in arrhythmogenic right ventricular cardiomyopathy in North America and Europe / R.T. Carrick, C. De Marco, A. Gasperetti, L.P. Bosman, J. Gourraud, A. Trancuccio, A. Mazzanti, B. Murray, C. Pendleton, C. Tichnell, H. Tandri, K. Zeppenfeld, A.A.M. Wilde, B. Davies, C. Seifer, J.D. Roberts, J.S. Healey, C. Macintyre, W. Alqarawi, R. Tadros, M.J. Cutler, M. Targetti, L. Calò, F. Vitali, M. Bertini, P. Compagnucci, M. Casella, A. Dello Russo, C. Cappelletto, A. De Luca, D. Stolfo, F. Duru, H.K. Jensen, A. Svensson, P. Dahlberg, N.E. Hasselberg, A. Di Marco, P. Jordà, E. Arbelo, Z. Moreno Weidmann, K. Borowiec, A. Delinière, E.K. Biernacka, J.P. van Tintelen, P.G. Platonov, I. Olivotto, A.M. Saguner, K.H. Haugaa, M. Cox, C. Tondo, M. Merlo, A.D. Krahn, A.S.J.M. Te Riele, K.C. Wu, H. Calkins, C.A. James, J. Cadrin-Tourigny. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - (2024), pp. ehad799.1-ehad799.11. [Epub ahead of print] [10.1093/eurheartj/ehad799]

Implantable cardioverter defibrillator use in arrhythmogenic right ventricular cardiomyopathy in North America and Europe

C. Tondo;
2024

Abstract

Background and aims: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. Methods: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. Results: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. Conclusions: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.
Arrhythmogenic right ventricular cardiomyopathy; Implantable cardioverter-defibrillator; Primary prevention; Sudden cardiac death; Ventricular arrhythmia
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2024
9-gen-2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
ehad799.pdf

accesso aperto

Descrizione: Online First
Tipologia: Publisher's version/PDF
Dimensione 1.44 MB
Formato Adobe PDF
1.44 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1023658
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact