This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.

Intra-Cardiac versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion with a Watchman FLX Device / L.E. Pastormerlo, C. Tondo, G. Fassini, A. Nicosia, F. Ronco, M. Contarini, G. Giacchi, C. Grasso, G. Casu, M.R. Romeo, P. Mazzone, L. Limite, G. Caramanno, S. Geraci, P. Pagnotta, M. Chiarito, C. Tamburino, S. Berti. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:20(2023 Oct 20), pp. 6658.1-6658.10. [10.3390/jcm12206658]

Intra-Cardiac versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion with a Watchman FLX Device

C. Tondo
Secondo
;
C. Grasso;
2023

Abstract

This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.
No
English
echocardiography; intra-cardiac; left atrial appendage occlusion; transesophageal
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
Goal 3: Good health and well-being
20-ott-2023
MDPI
12
20
6658
1
10
10
Pubblicato
Periodico con rilevanza internazionale
pubmed
scopus
crossref
Aderisco
info:eu-repo/semantics/article
Intra-Cardiac versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion with a Watchman FLX Device / L.E. Pastormerlo, C. Tondo, G. Fassini, A. Nicosia, F. Ronco, M. Contarini, G. Giacchi, C. Grasso, G. Casu, M.R. Romeo, P. Mazzone, L. Limite, G. Caramanno, S. Geraci, P. Pagnotta, M. Chiarito, C. Tamburino, S. Berti. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:20(2023 Oct 20), pp. 6658.1-6658.10. [10.3390/jcm12206658]
open
Prodotti della ricerca::01 - Articolo su periodico
18
262
Article (author)
Periodico con Impact Factor
L.E. Pastormerlo, C. Tondo, G. Fassini, A. Nicosia, F. Ronco, M. Contarini, G. Giacchi, C. Grasso, G. Casu, M.R. Romeo, P. Mazzone, L. Limite, G. Cara...espandi
File in questo prodotto:
File Dimensione Formato  
INTRACARDIAC.pdf

accesso aperto

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 960.78 kB
Formato Adobe PDF
960.78 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1023637
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
  • OpenAlex 8
social impact