Objective. Closed loop cardiovascular (CV) and cerebrovascular (CBV) variability interactions are assessed via transfer entropy (TE) from systolic arterial pressure (SAP) to heart period (HP) and vice versa and from mean arterial pressure (MAP) to mean cerebral blood velocity (MCBv) and vice versa. This analysis is exploited to assess the efficiency of baroreflex and cerebral autoregulation. This study aims at characterizing CV and CBV controls in postural orthostatic tachycardiac syndrome (POTS) subjects experiencing exaggerated sympathetic response during orthostatic challenge via unconditional TE and TE conditioned on respiratory activity (R). Approach. In 18 healthy controls (age: 28 ± 13 yrs; 5 males, 13 females) and 15 POTS individuals (age: 29 ± 11 yrs; 3 males, 12 females) we acquired beat-to-beat variability of HP, SAP, MAP and MCBv and two R signals, namely respiratory chest movement (RCM) and capnogram (CAP). Recordings were made at sitting rest and during active standing (STAND). TE was computed via vector autoregressive approach. Main results. We found that: (i) when assessing CV interactions, the increase of the TE from SAP to HP during STAND, indicating baroreflex activation, is detected solely when conditioning on RCM; (ii) when assessing CBV interactions, the impact of R on the TE computation is negligible; (iii) POTS shows baroreflex impairment during STAND; (iv) POTS exhibits a normal CBV response to STAND. Significance. TE is useful for detecting the impairment of specific regulatory mechanisms in POTS. Moreover, using different R signals highlights the sensitivity of CV and CBV controls to specific R aspects.

Evaluation of cardiovascular and cerebrovascular control mechanisms in postural orthostatic tachycardia syndrome via conditional transfer entropy: the impact of the respiratory signal type / F. Gelpi, V. Bari, B. Cairo, B. De Maria, R. Wells, M. Baumert, A. Porta. - In: PHYSIOLOGICAL MEASUREMENT. - ISSN 0967-3334. - 44:(2023 Jun), pp. 064001.1-064001.17. [10.1088/1361-6579/acdb47]

Evaluation of cardiovascular and cerebrovascular control mechanisms in postural orthostatic tachycardia syndrome via conditional transfer entropy: the impact of the respiratory signal type

F. Gelpi
Primo
;
V. Bari
Secondo
;
B. Cairo;A. Porta
Ultimo
2023

Abstract

Objective. Closed loop cardiovascular (CV) and cerebrovascular (CBV) variability interactions are assessed via transfer entropy (TE) from systolic arterial pressure (SAP) to heart period (HP) and vice versa and from mean arterial pressure (MAP) to mean cerebral blood velocity (MCBv) and vice versa. This analysis is exploited to assess the efficiency of baroreflex and cerebral autoregulation. This study aims at characterizing CV and CBV controls in postural orthostatic tachycardiac syndrome (POTS) subjects experiencing exaggerated sympathetic response during orthostatic challenge via unconditional TE and TE conditioned on respiratory activity (R). Approach. In 18 healthy controls (age: 28 ± 13 yrs; 5 males, 13 females) and 15 POTS individuals (age: 29 ± 11 yrs; 3 males, 12 females) we acquired beat-to-beat variability of HP, SAP, MAP and MCBv and two R signals, namely respiratory chest movement (RCM) and capnogram (CAP). Recordings were made at sitting rest and during active standing (STAND). TE was computed via vector autoregressive approach. Main results. We found that: (i) when assessing CV interactions, the increase of the TE from SAP to HP during STAND, indicating baroreflex activation, is detected solely when conditioning on RCM; (ii) when assessing CBV interactions, the impact of R on the TE computation is negligible; (iii) POTS shows baroreflex impairment during STAND; (iv) POTS exhibits a normal CBV response to STAND. Significance. TE is useful for detecting the impairment of specific regulatory mechanisms in POTS. Moreover, using different R signals highlights the sensitivity of CV and CBV controls to specific R aspects.
English
active standing; autonomic nervous system; baroreflex; cerebral autoregulation; cerebral blood flow; heart rate variability; vector autoregresssive model
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
Articolo
Esperti anonimi
Ricerca applicata
Pubblicazione scientifica
giu-2023
19-giu-2023
IOP Publishing Limited
44
064001
1
17
17
Pubblicato
Periodico con rilevanza internazionale
manual
Aderisco
info:eu-repo/semantics/article
Evaluation of cardiovascular and cerebrovascular control mechanisms in postural orthostatic tachycardia syndrome via conditional transfer entropy: the impact of the respiratory signal type / F. Gelpi, V. Bari, B. Cairo, B. De Maria, R. Wells, M. Baumert, A. Porta. - In: PHYSIOLOGICAL MEASUREMENT. - ISSN 0967-3334. - 44:(2023 Jun), pp. 064001.1-064001.17. [10.1088/1361-6579/acdb47]
open
Prodotti della ricerca::01 - Articolo su periodico
7
262
Article (author)
Periodico con Impact Factor
F. Gelpi, V. Bari, B. Cairo, B. De Maria, R. Wells, M. Baumert, A. Porta
File in questo prodotto:
File Dimensione Formato  
Gelpi_PMEA_2023.pdf

accesso aperto

Descrizione: Paper
Tipologia: Publisher's version/PDF
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1022865
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
  • OpenAlex ND
social impact