The hamstring tendons are among the most common autografts used for anterior cruciate ligament reconstruction. Typically, the ipsilateral knee's gracilis and semitendinosus tendons are harvested. More recently, studies have described the use of just 1 of the tendons (the semitendinosus [ST]) in a tripled or quadrupled configuration, particularly in all-inside reconstructions. Instead of using a double gracilis and ST, a quadrupled ST tendon allows for a graft with enough diameter to more closely mimic the natural anterior cruciate ligament while lowering the likelihood of graft rupture. The use of tourniquets has been reported to increase the risk of complications, particularly deep vein thrombosis. This Technical Note describes an anterior cruciate ligament reconstruction performed with a quadrupled ST, without the use of a tourniquet, and with only the reamers and a tibial guide as surgical instrumentation.

Quadrupled Semitendinosus Anterior Cruciate Ligament Reconstruction Without the Use of Tourniquet and Minimal Instrumentation: The “Double D” Technique / R. D'Ambrosi, N. Ursino, F. Di Feo. - In: ARTHROSCOPY TECHNIQUES. - ISSN 2212-6287. - 12:9(2023 Sep), pp. e1589-e1593. [10.1016/j.eats.2023.05.008]

Quadrupled Semitendinosus Anterior Cruciate Ligament Reconstruction Without the Use of Tourniquet and Minimal Instrumentation: The “Double D” Technique

R. D'Ambrosi
Primo
;
2023

Abstract

The hamstring tendons are among the most common autografts used for anterior cruciate ligament reconstruction. Typically, the ipsilateral knee's gracilis and semitendinosus tendons are harvested. More recently, studies have described the use of just 1 of the tendons (the semitendinosus [ST]) in a tripled or quadrupled configuration, particularly in all-inside reconstructions. Instead of using a double gracilis and ST, a quadrupled ST tendon allows for a graft with enough diameter to more closely mimic the natural anterior cruciate ligament while lowering the likelihood of graft rupture. The use of tourniquets has been reported to increase the risk of complications, particularly deep vein thrombosis. This Technical Note describes an anterior cruciate ligament reconstruction performed with a quadrupled ST, without the use of a tourniquet, and with only the reamers and a tibial guide as surgical instrumentation.
Settore MED/33 - Malattie Apparato Locomotore
set-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
QUADRUPLED SEMITENDINOSUS.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.46 MB
Formato Adobe PDF
1.46 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1022261
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact