The use of telerobots for surgery, military missions or rescue activities are increasingly commonplace, and so are guidelines to achieve an ergonomic design and optimal system-operator performance. However, in medical device manufacturing, in particular for fine-manipulation and highly precise operations, the existing human-machine interface and interaction (HMII) design standards to date are insufficient to ensure a cost-effective ergonomic teleoperation solution, that complies with the learnability, usability, dependability and efficiency required for this case-study. We analyze the most relevant human-system interface and interaction requirements for telerobotic systems applied to medical device manufacturing, and expand on the current standards with knowledge from recent research results in this field. We further our contribution by proposing a use-case-based telerobotic system architecture and experimental setup for human-centered evaluation of the telerobotic system HMII design.

User-Centered Evaluation Framework for Telerobot Interface and Interaction factors -- A Case Study on Medical Device Manufacturing / I.F. Fernandes Ramos, K. Sagar, P. Long, E. Damiani, M. Chiara Leva, G. Gianini - In: The 33rd European Safety and Reliability Conference (ESREL 2023) / [a cura di] M.P. Brito, T. Aven, P. Baraldi, M. Čepin, E. Zio. - SINGAPORE : RESEARCH PUBLISHING, 2023 Sep. - ISBN 978-981-18-8071-1. - pp. 2316-2317 (( Intervento presentato al 33. convegno European Safety and Reliability Conference tenutosi a Southampton nel 2023 [10.3850/978-981-18-8071-1_P295-cd].

User-Centered Evaluation Framework for Telerobot Interface and Interaction factors -- A Case Study on Medical Device Manufacturing

I.F. Fernandes Ramos
Primo
;
E. Damiani;G. Gianini
2023

Abstract

The use of telerobots for surgery, military missions or rescue activities are increasingly commonplace, and so are guidelines to achieve an ergonomic design and optimal system-operator performance. However, in medical device manufacturing, in particular for fine-manipulation and highly precise operations, the existing human-machine interface and interaction (HMII) design standards to date are insufficient to ensure a cost-effective ergonomic teleoperation solution, that complies with the learnability, usability, dependability and efficiency required for this case-study. We analyze the most relevant human-system interface and interaction requirements for telerobotic systems applied to medical device manufacturing, and expand on the current standards with knowledge from recent research results in this field. We further our contribution by proposing a use-case-based telerobotic system architecture and experimental setup for human-centered evaluation of the telerobotic system HMII design.
English
Telerobotics; Human-in-the-loop; Medical device manufacturing; Standards; EEG; Eye-tracking
Settore INF/01 - Informatica
Settore ING-INF/05 - Sistemi di Elaborazione delle Informazioni
Settore INFO-01/A - Informatica
Intervento a convegno
Sì, ma tipo non specificato
Pubblicazione scientifica
   Collaborative Intelligence for Safety Critical systems (CISC)
   CISC
   EUROPEAN COMMISSION
   H2020
   955901
The 33rd European Safety and Reliability Conference (ESREL 2023)
M.P. Brito, T. Aven, P. Baraldi, M. Čepin, E. Zio
SINGAPORE
RESEARCH PUBLISHING
set-2023
2316
2317
2
978-981-18-8071-1
Volume a diffusione internazionale
Diamond
European Safety and Reliability Conference
Southampton
2023
33
https://www.rpsonline.com.sg/proceedings/esrel2023/html/P295.html
crossref
Aderisco
I.F. Fernandes Ramos, K. Sagar, P. Long, E. Damiani, M. Chiara Leva, G. Gianini
Book Part (author)
open
273
User-Centered Evaluation Framework for Telerobot Interface and Interaction factors -- A Case Study on Medical Device Manufacturing / I.F. Fernandes Ramos, K. Sagar, P. Long, E. Damiani, M. Chiara Leva, G. Gianini - In: The 33rd European Safety and Reliability Conference (ESREL 2023) / [a cura di] M.P. Brito, T. Aven, P. Baraldi, M. Čepin, E. Zio. - SINGAPORE : RESEARCH PUBLISHING, 2023 Sep. - ISBN 978-981-18-8071-1. - pp. 2316-2317 (( Intervento presentato al 33. convegno European Safety and Reliability Conference tenutosi a Southampton nel 2023 [10.3850/978-981-18-8071-1_P295-cd].
info:eu-repo/semantics/bookPart
6
Prodotti della ricerca::03 - Contributo in volume
File in questo prodotto:
File Dimensione Formato  
P295.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 60.26 kB
Formato Adobe PDF
60.26 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1021892
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact