The MiniMed™ 780G is a second-generation automated insulin delivery system that implements a modified proportional-integral-derivative algorithm with some features of an MD-Logic artificial pancreas algorithm. The system may deliver automatic correction boluses up to every 5 min, and it allows the user to choose between three glucose target setpoints (100, 110 and 120 mg/dL). We aimed to review the current evidence on this device in children, adolescents, and young adults living with type 1 diabetes. We screened 783 papers, but only 31 manuscripts were included in this review. Data on metabolic outcomes show that this system is safe as regards severe hypoglycaemia and diabetic ketoacidosis. The glycated haemoglobin may drop to levels about 7%, with CGM reports showing a time in range of 75-80%. The time above range and the time below range are within the recommended target in most of the subjects. Few studies evaluated the psychological outcomes. This system seems to be more effective than the first-generation automated insulin delivery systems. The MiniMed™ 780G has been associated with an improvement in sleep quality in subjects living with diabetes and their caregivers, along with an improvement in treatment satisfaction. Psychological distress is as reduced as the glucose control is improved. We also discuss some case reports describing particular situations in clinical practice. Finally, we think that data show that this system is a further step towards the improvement of the treatment of diabetes as concerns both metabolic and psychological outcomes.

Safety, Metabolic and Psychological Outcomes of Medtronic MiniMed 780G™ in Children, Adolescents and Young Adults: A Systematic Review / S. Passanisi, F. Lombardo, C. Mameli, B. Bombaci, M. Macedoni, G. Zuccotti, K. Dovc, T. Battelino, G. Salzano, M. Delvecchio. - (2023), pp. 1-23. [10.1007/s13300-023-01501-6]

Safety, Metabolic and Psychological Outcomes of Medtronic MiniMed 780G™ in Children, Adolescents and Young Adults: A Systematic Review

C. Mameli;G. Zuccotti;
2023

Abstract

The MiniMed™ 780G is a second-generation automated insulin delivery system that implements a modified proportional-integral-derivative algorithm with some features of an MD-Logic artificial pancreas algorithm. The system may deliver automatic correction boluses up to every 5 min, and it allows the user to choose between three glucose target setpoints (100, 110 and 120 mg/dL). We aimed to review the current evidence on this device in children, adolescents, and young adults living with type 1 diabetes. We screened 783 papers, but only 31 manuscripts were included in this review. Data on metabolic outcomes show that this system is safe as regards severe hypoglycaemia and diabetic ketoacidosis. The glycated haemoglobin may drop to levels about 7%, with CGM reports showing a time in range of 75-80%. The time above range and the time below range are within the recommended target in most of the subjects. Few studies evaluated the psychological outcomes. This system seems to be more effective than the first-generation automated insulin delivery systems. The MiniMed™ 780G has been associated with an improvement in sleep quality in subjects living with diabetes and their caregivers, along with an improvement in treatment satisfaction. Psychological distress is as reduced as the glucose control is improved. We also discuss some case reports describing particular situations in clinical practice. Finally, we think that data show that this system is a further step towards the improvement of the treatment of diabetes as concerns both metabolic and psychological outcomes.
Advanced hybrid closed loop; Automated insulin delivery; CGM metrics; Medtronic 780G; MiniMed 780G; Quality of life; Type 1 diabetes
Settore MED/38 - Pediatria Generale e Specialistica
2023
1-dic-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
safety and metabolic outcome 780_diabetes therapy 2023.pdf

accesso aperto

Descrizione: Online First
Tipologia: Publisher's version/PDF
Dimensione 439.51 kB
Formato Adobe PDF
439.51 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1019629
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact