Background: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. Objectives: This study aimed to determine whether device position and asymmetry are associated with these outcomes. Methods: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. Results: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). Conclusions: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.

Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry / M. Simonato, B.K. Whisenant, A. Unbehaun, J. Kempfert, H.B. Ribeiro, R. Kornowski, M. Erlebach, S. Bleiziffer, S. Windecker, T. Pilgrim, D. Tomii, M. Guerrero, Md, K. Yousif Ahmad, J.K. Forrest, M. Montorfano, M. Ancona, M. Adam, H. Wienemann, A. Finkelstein, P. Villablanca, P. Codner, D. Hildick-Smith, E. Ferrari, A. Sonia Petronio, J. Shamekhi, P. Presbitero, G. Bruschi, T. Rudolph, A. Cerillo, D. Attias, M. Nejjari, A. Abizaid, M. Felippi de Sá Marchi, E. Horlick, H. Wijeysundera, M. Andreas, A. Thukkani, M. Agrifoglio, A. Iadanza, L. Matthew Baer, M.G. Nanna, D. Dvir. - In: JACC. CARDIOVASCULAR INTERVENTIONS. - ISSN 1876-7591. - 16:21(2023 Oct 13), pp. 2615-2627. [10.1016/j.jcin.2023.08.047]

Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry

M. Agrifoglio;
2023

Abstract

Background: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. Objectives: This study aimed to determine whether device position and asymmetry are associated with these outcomes. Methods: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. Results: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). Conclusions: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.
depth of implantation; left ventricular outflow tract obstruction; mitral valve-in-valve; positioning; residual stenosis; SAPIEN 3
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
13-ott-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
JACC cardiovasc interv 2023 mitral vivid registry.pdf

accesso riservato

Descrizione: New Research Paper
Tipologia: Publisher's version/PDF
Dimensione 1.75 MB
Formato Adobe PDF
1.75 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1018374
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact