A double network hydrogel based on Poly(vinyl-alcohol) (PVA) cross-linked with Glutaraldehyde (GTA) was recently developed by using self-assembling phenylalanine (Phe) peptide derivative (Fmoc-Phe-Phe-OMe), with the aim to improve the mechanical-elastic properties of PVA-GTA hydrogels. In this study, a characterization of the properties of Xylenol Orange based Fricke gel dosimeters obtained by infusing a Fricke solution into the double network hydrogel was performed. The gel dosimeters were irradiated with 6 MV and 15 MV X-rays produced by a medical linear accelerator and investigated by means optical absorbance measurements. The double network hydrogel formulation maintained a satisfactory level of radiological water-equivalence within the investigated radiotherapy range. Fricke gel dosimeters prepared with such network kept the desired properties of independence of the response of the dose rate and energy in the investigated intervals. Furthermore, the addition of self-assembling Phe peptide derivative proved not avoid the motion of radio-inducted ferric ions into the hydrogel, probably maintaining the main characteristics of the standard, no Phe peptide infused, formulation. The time course of formation of the optical response after the irradiation was observed to be similar to what previously measured in traditional PVA-GTA Fricke gel dosimeters, while a decrease of the sensitivity to radiation dose of the order of 30% was found. The extent of the decrease does not seem such as to impair the use of these dosimeters for evaluation of doses typical of radiation therapy applications. The overall dosimetric properties, coupled with the mechanical-elastic characteristics of the double network hydrogel, pave theway to the development of phantoms able both to mimic the deformation of organs possibly occurring during radiotherapy treatments and at the same time to assess the 3D dose distribution within such volumes.

Dosimetric characterization of double network Fricke hydrogel based on PVA-GTA and phenylalanine peptide derivative / S. Gallo, S. Locarno, E. Brambilla, C. Lenardi, E. Pignoli, I. Veronese. - In: JOURNAL OF PHYSICS. D, APPLIED PHYSICS. - ISSN 1361-6463. - 2024:57(2023 Nov 21), pp. 075303.1-075303.11. [10.1088/1361-6463/ad0987]

Dosimetric characterization of double network Fricke hydrogel based on PVA-GTA and phenylalanine peptide derivative

S. Gallo
Primo
Conceptualization
;
S. Locarno
Secondo
Investigation
;
E. Brambilla
Methodology
;
C. Lenardi
Validation
;
I. Veronese
Ultimo
Supervision
2023

Abstract

A double network hydrogel based on Poly(vinyl-alcohol) (PVA) cross-linked with Glutaraldehyde (GTA) was recently developed by using self-assembling phenylalanine (Phe) peptide derivative (Fmoc-Phe-Phe-OMe), with the aim to improve the mechanical-elastic properties of PVA-GTA hydrogels. In this study, a characterization of the properties of Xylenol Orange based Fricke gel dosimeters obtained by infusing a Fricke solution into the double network hydrogel was performed. The gel dosimeters were irradiated with 6 MV and 15 MV X-rays produced by a medical linear accelerator and investigated by means optical absorbance measurements. The double network hydrogel formulation maintained a satisfactory level of radiological water-equivalence within the investigated radiotherapy range. Fricke gel dosimeters prepared with such network kept the desired properties of independence of the response of the dose rate and energy in the investigated intervals. Furthermore, the addition of self-assembling Phe peptide derivative proved not avoid the motion of radio-inducted ferric ions into the hydrogel, probably maintaining the main characteristics of the standard, no Phe peptide infused, formulation. The time course of formation of the optical response after the irradiation was observed to be similar to what previously measured in traditional PVA-GTA Fricke gel dosimeters, while a decrease of the sensitivity to radiation dose of the order of 30% was found. The extent of the decrease does not seem such as to impair the use of these dosimeters for evaluation of doses typical of radiation therapy applications. The overall dosimetric properties, coupled with the mechanical-elastic characteristics of the double network hydrogel, pave theway to the development of phantoms able both to mimic the deformation of organs possibly occurring during radiotherapy treatments and at the same time to assess the 3D dose distribution within such volumes.
A double network hydrogel based on Poly(vinyl-alcohol) (PVA) cross-linked with Glutaraldehyde (GTA) was recently developed by using self-assembling phenylalanine (Phe) peptide derivative (Fmoc-Phe-Phe-OMe), with the aim to improve the mechanical-elastic properties of PVA-GTA hydrogels. In this study, a characterization of the properties of Xylenol Orange based Fricke gel dosimeters obtained by infusing a Fricke solution into the double network hydrogel was performed. The gel dosimeters were irradiated with 6 MV and 15 MV X-rays produced by a medical linear accelerator and investigated by means optical absorbance measurements. The double network hydrogel formulation maintained a satisfactory level of radiological water-equivalence within the investigated radiotherapy range. Fricke gel dosimeters prepared with such network kept the desired properties of independence of the response of the dose rate and energy in the investigated intervals. Furthermore, the addition of self-assembling Phe peptide derivative proved not avoid the motion of radio-inducted ferric ions into the hydrogel, probably maintaining the main characteristics of the standard, no Phe peptide infused, formulation. The time course of formation of the optical response after the irradiation was observed to be similar to what previously measured in traditional PVA-GTA Fricke gel dosimeters, while a decrease of the sensitivity to radiation dose of the order of 30% was found. The extent of the decrease does not seem such as to impair the use of these dosimeters for evaluation of doses typical of radiation therapy applications.
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore CHIM/06 - Chimica Organica
21-nov-2023
3-nov-2023
https://iopscience.iop.org/article/10.1088/1361-6463/ad0987
Article (author)
File in questo prodotto:
File Dimensione Formato  
Pubblicazione4.pdf

accesso aperto

Descrizione: Articolo
Tipologia: Publisher's version/PDF
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1018368
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact