Purpose: To compare pathologic and healthy tendons using shear-wave elastography (SWE). Methods: A systematic review with meta-analysis was done searching Pubmed and EMBASE up to September 2022. Prospective, retrospective and cross-sectional studies that used SWE in the assessment of pathologic tendons versus control were included. Our primary outcome were SWE velocity (m/s) and stiffness (kPa). Methodological quality was assessed by the methodological index for non-randomized studies (MINORS). We used the mean difference (MD) with corresponding 95% confidence intervals (CIs) to quantify effects between groups. We performed sensitivity analysis in case of high heterogeneity, after excluding poor quality studies according to MINORS assessment. We used Grades of Recommendation, Assessment, Development and Evaluation to evaluate the certainty of evidence (CoE). Results: Overall, 16 studies with 676 pathologic tendons (188 Achilles, 142 patellar, 96 supraspinatus, 250 mixed) and 723 control tendons (484 healthy; 239 contralateral tendon) were included. Five studies (31.3%) were judged as poor methodological quality. Shear-wave velocity and stiffness meta-analyses showed high heterogeneity. According to a sensitivity analysis, pathologic tendons had a lower shear wave velocity (MD of - 1.69 m/s; 95% CI 1.85; - 1.52; n = 274; I2 50%) compared to healthy tendons with very low CoE. Sensitivity analysis on stiffness still showed high heterogeneity. Conclusion: Pathological tendons may have reduced SWE velocity compared to controls, but the evidence is very uncertain. Future robust high-quality longitudinal studies and clear technical indications on the use of this tool are needed. Protocol: PROSPERO identifier: CRD42023405410 CLINICAL RELEVANCE STATEMENT: SWE is a relatively recent modality that may increase sensitivity and diagnostic accuracy of conventional ultrasound imaging promoting early detection of tendinopathy. Non-negligible heterogeneity has been observed in included studies, so our findings may encourage the conduct of future high-quality longitudinal studies which can provide clear technical indications on the use of this promising tool in tendon imaging.
Shear-wave elastography for the evaluation of tendinopathies: a systematic review and meta-analysis / D. Albano, M. Basile, S. Gitto, C. Messina, S. Longo, S. Fusco, Z. Snoj, S. Gianola, S. Bargeri, G. Castellini, L.M. Sconfienza. - In: LA RADIOLOGIA MEDICA. - ISSN 1826-6983. - (2023), pp. 1-11. [Epub ahead of print] [10.1007/s11547-023-01732-4]
Shear-wave elastography for the evaluation of tendinopathies: a systematic review and meta-analysis
D. Albano
Primo
;M. BasileSecondo
;S. Gitto;C. Messina;S. Longo;S. Fusco;G. Castellini;L.M. Sconfienza
Ultimo
2023
Abstract
Purpose: To compare pathologic and healthy tendons using shear-wave elastography (SWE). Methods: A systematic review with meta-analysis was done searching Pubmed and EMBASE up to September 2022. Prospective, retrospective and cross-sectional studies that used SWE in the assessment of pathologic tendons versus control were included. Our primary outcome were SWE velocity (m/s) and stiffness (kPa). Methodological quality was assessed by the methodological index for non-randomized studies (MINORS). We used the mean difference (MD) with corresponding 95% confidence intervals (CIs) to quantify effects between groups. We performed sensitivity analysis in case of high heterogeneity, after excluding poor quality studies according to MINORS assessment. We used Grades of Recommendation, Assessment, Development and Evaluation to evaluate the certainty of evidence (CoE). Results: Overall, 16 studies with 676 pathologic tendons (188 Achilles, 142 patellar, 96 supraspinatus, 250 mixed) and 723 control tendons (484 healthy; 239 contralateral tendon) were included. Five studies (31.3%) were judged as poor methodological quality. Shear-wave velocity and stiffness meta-analyses showed high heterogeneity. According to a sensitivity analysis, pathologic tendons had a lower shear wave velocity (MD of - 1.69 m/s; 95% CI 1.85; - 1.52; n = 274; I2 50%) compared to healthy tendons with very low CoE. Sensitivity analysis on stiffness still showed high heterogeneity. Conclusion: Pathological tendons may have reduced SWE velocity compared to controls, but the evidence is very uncertain. Future robust high-quality longitudinal studies and clear technical indications on the use of this tool are needed. Protocol: PROSPERO identifier: CRD42023405410 CLINICAL RELEVANCE STATEMENT: SWE is a relatively recent modality that may increase sensitivity and diagnostic accuracy of conventional ultrasound imaging promoting early detection of tendinopathy. Non-negligible heterogeneity has been observed in included studies, so our findings may encourage the conduct of future high-quality longitudinal studies which can provide clear technical indications on the use of this promising tool in tendon imaging.File | Dimensione | Formato | |
---|---|---|---|
s11547-023-01732-4.pdf
accesso riservato
Descrizione: Article
Tipologia:
Publisher's version/PDF
Dimensione
2.37 MB
Formato
Adobe PDF
|
2.37 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.