Background: Our aim was to estimate the rates of not achieving a robust/above-average humoral response to the COVID-19 mRNA vaccine in people living with HIV (PLWH) who received ≥2 doses and to investigate the role of the CD4 and CD4/CD8 ratio in predicting the humoral response. Methods: We evaluated the humoral anti-SARS-CoV-2 response 1-month after the second and third doses of COVID-19 mRNA vaccine as a proportion of not achieving a robust/above- average response using two criteria: (i) a humoral threshold identified as a correlate of protection against SARS-CoV-2 (<90% vaccine efficacy): anti-RBD < 775 BAU/mL or anti-S < 298 BAU/mL, (ii) threshold of binding antibodies equivalent to average neutralization activity from the levels of binding ( nAb titer < 1:40): anti-RBD < 870 BAU/mL or anti-S < 1591 BAU/mL. PLWH were stratified according to the CD4 count and CD4/CD8 ratio at first dose. Logistic regression was used to compare the probability of not achieving robust/above-average responses. A mixed linear model was used to estimate the mean anti-RBD titer at various time points across the exposure groups. Results: a total of 1176 PLWH were included. The proportions of participants failing to achieve a robust/above- average response were significantly higher in participants with a lower CD4 and CD4/CD8 ratio, specifically, a clearer gradient was observed for the CD4 count. The CD4 count was a better predictor of the humoral response of the primary cycle than ratio. The third dose was pivotal in achieving a robust/above-average humoral response, at least for PLWH with CD4 > 200 cells/mm3 and a ratio > 0.6. Conclusions: A robust humoral response after a booster dose has not been reached by 50% of PLWH with CD4 < 200 cells mm3. In the absence of a validated correlate of protections in the Omicron era, the CD4 count remains the most solid marker to guide vaccination campaigns in PLWH.
SARS-CoV-2 mRNA Vaccine Response in People Living with HIV According to CD4 Count and CD4/CD8 Ratio / A. Vergori, A. Tavelli, G. Matusali, A.M. Azzini, M. Augello, V. Mazzotta, G.F. Pellicanò, A. Costantini, A. Cascio, A. De Vito, L. Marconi, E. Righi, A. Sartor, C. Pinnetti, F. Maggi, F. Bai, S. Lanini, S. Piconi, G. Levy Hara, G. Marchetti, M. Giannella, E. Tacconelli, A. d’Arminio Monforte, A. Antinori, A. Cozzi-Lepri. - In: VACCINES. - ISSN 2076-393X. - 11:11(2023 Oct 30), pp. 1664.1-1664.14. [10.3390/vaccines11111664]
SARS-CoV-2 mRNA Vaccine Response in People Living with HIV According to CD4 Count and CD4/CD8 Ratio
M. Augello;F. Bai;G. Marchetti;A. d’Arminio Monforte;
2023
Abstract
Background: Our aim was to estimate the rates of not achieving a robust/above-average humoral response to the COVID-19 mRNA vaccine in people living with HIV (PLWH) who received ≥2 doses and to investigate the role of the CD4 and CD4/CD8 ratio in predicting the humoral response. Methods: We evaluated the humoral anti-SARS-CoV-2 response 1-month after the second and third doses of COVID-19 mRNA vaccine as a proportion of not achieving a robust/above- average response using two criteria: (i) a humoral threshold identified as a correlate of protection against SARS-CoV-2 (<90% vaccine efficacy): anti-RBD < 775 BAU/mL or anti-S < 298 BAU/mL, (ii) threshold of binding antibodies equivalent to average neutralization activity from the levels of binding ( nAb titer < 1:40): anti-RBD < 870 BAU/mL or anti-S < 1591 BAU/mL. PLWH were stratified according to the CD4 count and CD4/CD8 ratio at first dose. Logistic regression was used to compare the probability of not achieving robust/above-average responses. A mixed linear model was used to estimate the mean anti-RBD titer at various time points across the exposure groups. Results: a total of 1176 PLWH were included. The proportions of participants failing to achieve a robust/above- average response were significantly higher in participants with a lower CD4 and CD4/CD8 ratio, specifically, a clearer gradient was observed for the CD4 count. The CD4 count was a better predictor of the humoral response of the primary cycle than ratio. The third dose was pivotal in achieving a robust/above-average humoral response, at least for PLWH with CD4 > 200 cells/mm3 and a ratio > 0.6. Conclusions: A robust humoral response after a booster dose has not been reached by 50% of PLWH with CD4 < 200 cells mm3. In the absence of a validated correlate of protections in the Omicron era, the CD4 count remains the most solid marker to guide vaccination campaigns in PLWH.File | Dimensione | Formato | |
---|---|---|---|
vaccines-11-01664.pdf
accesso aperto
Descrizione: Article
Tipologia:
Publisher's version/PDF
Dimensione
1.31 MB
Formato
Adobe PDF
|
1.31 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.