Therapeutic drug monitoring (TDM) is a useful tool for optimising the use of anti-TNF & alpha; inhibitors in patients with inflammatory bowel diseases (IBDs). Recently, point-of-care methods for the quantification of drug levels and anti-drug antibodies (ADAs) have been developed to overcome the limitations of conventional enzyme-linked immunoabsorbent assays (ELISAs). Here, we evaluated the performance, interchangeability, and agreement between an automated ELISA-based immunoassay (CHORUS Promonitor) and the lateral flow assay (RIDA(& REG;)QUICK) for the quantification of infliximab (IFX, n = 65) and adalimumab (ADM, n = 58) plasma levels in IBD patients. Thirty-two samples for IFX and twenty-three samples for ADM that tested positively for the presence of ADAs were also used. Overall, data analysis showed a good agreement of ADM trough concentrations (R-2 = 0.75) between the two assays as well as for ADA measurement (K > 0.8). However, IFX levels highlighted a weak correlation (R-2 = 0.58) between the two kits, with the RIDA(& REG;)QUICK assay overestimating IFX plasma values by 30% when compared to the CHORUS Promonitor kit. Results from this study show that the two assays are not quantitatively and qualitatively interchangeable due to substantial discrepancies in some results. Accordingly, the same assay should be used for the longitudinal follow-up of IBD patients.

Therapeutic Drug Monitoring of Anti-TNFα Inhibitors: A Matter of Cut-Off Ranges / S. Cheli, D. Savino, F. Penagini, G. Zuccotti, G. Zuin, E. Clementi, D. Cattaneo. - In: PHARMACEUTICS. - ISSN 1999-4923. - 15:7(2023 Jul), pp. 1834.1-1834.11. [10.3390/pharmaceutics15071834]

Therapeutic Drug Monitoring of Anti-TNFα Inhibitors: A Matter of Cut-Off Ranges

G. Zuccotti;E. Clementi;
2023

Abstract

Therapeutic drug monitoring (TDM) is a useful tool for optimising the use of anti-TNF & alpha; inhibitors in patients with inflammatory bowel diseases (IBDs). Recently, point-of-care methods for the quantification of drug levels and anti-drug antibodies (ADAs) have been developed to overcome the limitations of conventional enzyme-linked immunoabsorbent assays (ELISAs). Here, we evaluated the performance, interchangeability, and agreement between an automated ELISA-based immunoassay (CHORUS Promonitor) and the lateral flow assay (RIDA(& REG;)QUICK) for the quantification of infliximab (IFX, n = 65) and adalimumab (ADM, n = 58) plasma levels in IBD patients. Thirty-two samples for IFX and twenty-three samples for ADM that tested positively for the presence of ADAs were also used. Overall, data analysis showed a good agreement of ADM trough concentrations (R-2 = 0.75) between the two assays as well as for ADA measurement (K > 0.8). However, IFX levels highlighted a weak correlation (R-2 = 0.58) between the two kits, with the RIDA(& REG;)QUICK assay overestimating IFX plasma values by 30% when compared to the CHORUS Promonitor kit. Results from this study show that the two assays are not quantitatively and qualitatively interchangeable due to substantial discrepancies in some results. Accordingly, the same assay should be used for the longitudinal follow-up of IBD patients.
adalimumab; adalimumab antibodies; anti-infliximab antibodies; inflammatory bowel disease; infliximab; therapeutic drug monitoring
Settore MED/38 - Pediatria Generale e Specialistica
Settore BIO/14 - Farmacologia
lug-2023
27-giu-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
pharmaceutics-15-01834.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.09 MB
Formato Adobe PDF
1.09 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1013329
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact