Objectives: This study aims to evaluate the diagnostic performance of NIHSS extinction and inattention item, compared to the results of the Oxford Cognitive Screen (OCS) heart subtest. Additionally, the possible role of the NIHSS visual field subtest on the NIHSS extinction and inattention subtest performance is explored and discussed.Methods: We analysed scores on NIHSS extinction and inattention subtest, NIHSS visual field subtest, and OCS heart subtest on a sample of 118 post-stroke patients.Results: Compared to OCS heart subtest, the results on NIHSS extinction and inattention subtest showed an accuracy of 72.9% and a moderate agreement level (Cohen's kappa = 0.404). Furthermore, a decrease in NIHSS accuracy detecting neglect (61.1%) was observed in patients with pathological scores in NIHSS visual field item.Conclusions: Extreme caution is recommended for the diagnostic performance of extinction and inattention item of NIHSS. Signs of neglect may not be detected by NIHSS, and may be confused with visual field impairment.

Critical issue on the extinction and inattention subtest of NIHSS scale: an analysis on post-acute stroke patients attending inpatient rehabilitation / B. Basagni, B. Hakiki, S. Campagnini, E. Salvadori, A. Grippo, A. Paperini, C. Castagnoli, I. Hochleitner, A.M. Politi, P. Gemignani, I.E. Mosca, A. Franceschini, E.B. Bonotti, A. Sodero, A. Mannini, L. Pellicciari, A. Poggesi, C. Macchi, M.C. Carrozza, F. Cecchi. - In: BMC NEUROLOGY. - ISSN 1471-2377. - 21:1(2021 Dec 08), pp. 475.1-475.7. [10.1186/s12883-021-02499-9]

Critical issue on the extinction and inattention subtest of NIHSS scale: an analysis on post-acute stroke patients attending inpatient rehabilitation

E. Salvadori;
2021

Abstract

Objectives: This study aims to evaluate the diagnostic performance of NIHSS extinction and inattention item, compared to the results of the Oxford Cognitive Screen (OCS) heart subtest. Additionally, the possible role of the NIHSS visual field subtest on the NIHSS extinction and inattention subtest performance is explored and discussed.Methods: We analysed scores on NIHSS extinction and inattention subtest, NIHSS visual field subtest, and OCS heart subtest on a sample of 118 post-stroke patients.Results: Compared to OCS heart subtest, the results on NIHSS extinction and inattention subtest showed an accuracy of 72.9% and a moderate agreement level (Cohen's kappa = 0.404). Furthermore, a decrease in NIHSS accuracy detecting neglect (61.1%) was observed in patients with pathological scores in NIHSS visual field item.Conclusions: Extreme caution is recommended for the diagnostic performance of extinction and inattention item of NIHSS. Signs of neglect may not be detected by NIHSS, and may be confused with visual field impairment.
Heminattention; Hemineglect; NIHSS; Rehabilitation; Stroke; Visual field
Settore M-PSI/02 - Psicobiologia e Psicologia Fisiologica
8-dic-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
Basagni_BMC Neurology_2021.pdf

accesso aperto

Descrizione: Research
Tipologia: Publisher's version/PDF
Dimensione 1.26 MB
Formato Adobe PDF
1.26 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1009108
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
  • OpenAlex ND