Background: While intraoperative neuromonitoring (IONM) helps the early identification of recurrent laryngeal nerve (RLN) damage, IONM’s role in RLN damage prevention is not defined, given the lack of large studies on the subject. Methods: In a PRISMA-compliant framework, all original thyroid surgery prospective studies providing early postoperative endoscopic data for all patients were pooled in a random-effects meta-analysis. We compared the temporary (and definitive where available) RLN damage rates according to IONM use and IONM type (intermittent, I-IONM, or continuous, C-IONM). Results: We identified 2358 temporary and 257 definitive RLN injuries in, respectively, 73,325 and 66,476 nerves at risk. The pooled temporary and definitive RLN injury rates were, respectively, 3.15% and 0.422% considering all procedures, 3.29% and 0.409% in cases using IONM, and 3.16% and 0.463 in cases not using IONM. I-IONM and C-IONM, respectively, showed a pooled temporary RLN injury rate of 2.48% and 2.913% and a pooled definitive injury rate of 0.395% and 0.4%. All pooled rates had largely overlapping 95% confidence intervals. Conclusions: Our data suggest that IONM does not affect the temporary or definitive RLN injury rate following thyroidectomy, though its use can be advised in selected cases and for bilateral palsy prevention.
Intraoperative Neuromonitoring Does Not Reduce the Risk of Temporary and Definitive Recurrent Laryngeal Nerve Damage during Thyroid Surgery: A Systematic Review and Meta-Analysis of Endoscopic Findings from 73,325 Nerves at Risk / A.T. Cozzi, A. Ottavi, P. Lozza, A. Maccari, R. Borloni, L. Nitro, E.G. Felisati, A. Alliata, B. Martino, G. Cacioppo, M. Fuccillo, C. Rosso, C. Pipolo, G. Felisati, L. De Pasquale, A.M. Saibene. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 13:10(2023), pp. 1429.1-1429.11. [Epub ahead of print] [10.3390/jpm13101429]
Intraoperative Neuromonitoring Does Not Reduce the Risk of Temporary and Definitive Recurrent Laryngeal Nerve Damage during Thyroid Surgery: A Systematic Review and Meta-Analysis of Endoscopic Findings from 73,325 Nerves at Risk
A.T. CozziCo-primo
;A. OttaviCo-primo
;A. Alliata;G. Cacioppo;C. Rosso;C. Pipolo;G. Felisati;A.M. Saibene
Co-ultimo
2023
Abstract
Background: While intraoperative neuromonitoring (IONM) helps the early identification of recurrent laryngeal nerve (RLN) damage, IONM’s role in RLN damage prevention is not defined, given the lack of large studies on the subject. Methods: In a PRISMA-compliant framework, all original thyroid surgery prospective studies providing early postoperative endoscopic data for all patients were pooled in a random-effects meta-analysis. We compared the temporary (and definitive where available) RLN damage rates according to IONM use and IONM type (intermittent, I-IONM, or continuous, C-IONM). Results: We identified 2358 temporary and 257 definitive RLN injuries in, respectively, 73,325 and 66,476 nerves at risk. The pooled temporary and definitive RLN injury rates were, respectively, 3.15% and 0.422% considering all procedures, 3.29% and 0.409% in cases using IONM, and 3.16% and 0.463 in cases not using IONM. I-IONM and C-IONM, respectively, showed a pooled temporary RLN injury rate of 2.48% and 2.913% and a pooled definitive injury rate of 0.395% and 0.4%. All pooled rates had largely overlapping 95% confidence intervals. Conclusions: Our data suggest that IONM does not affect the temporary or definitive RLN injury rate following thyroidectomy, though its use can be advised in selected cases and for bilateral palsy prevention.File | Dimensione | Formato | |
---|---|---|---|
IONM doesn't protect nerves, SRMA (2023).pdf
accesso aperto
Descrizione: Review
Tipologia:
Publisher's version/PDF
Dimensione
424.38 kB
Formato
Adobe PDF
|
424.38 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.