A major challenge during autonomous navigation in endovascular interventions is the complexity of operating in a deformable but constrained workspace with an instrument. Simulation of deformations for it can provide a cost-effective training platform for path planning. Aim of this study is to develop a realistic, auto-adaptive, and visually plausible simulator to predict vessels’ global deformation induced by the robotic catheter's contact and cyclic heartbeat motion. Based on a Position-based Dynamics (PBD) approach for vessel modeling, Particle Swarm Optimization (PSO) algorithm is employed for an auto-adaptive calibration of PBD deformation parameters and of the vessels movement due to a heartbeat. In-vitro experiments were conducted and compared with in-silico results. The end-user evaluation results were reported through quantitative performance metrics and a 5-Point Likert Scale questionnaire. Compared with literature, this simulator has an error of 0.23±0.13% for deformation and 0.30±0.85mm for the aortic root displacement. In-vitro experiments show an error of 1.35±1.38mm for deformation prediction. The end-user evaluation results show that novices are more accustomed to using joystick controllers, and cardiologists are more satisfied with the visual authenticity. The real-time and accurate performance of the simulator make this framework suitable for creating a dynamic environment for autonomous navigation of robotic catheters.

Position-based dynamics simulator of vessel deformations for path planning in robotic endovascular catheterization / Z. Li, E. Manzionna, G. Monizzi, A. Mastrangelo, M.E. Mancini, D. Andreini, J. Dankelman, E. De Momi. - In: MEDICAL ENGINEERING & PHYSICS. - ISSN 1350-4533. - 110:(2022 Dec), pp. 103920.1-103920.11. [10.1016/j.medengphy.2022.103920]

Position-based dynamics simulator of vessel deformations for path planning in robotic endovascular catheterization

G. Monizzi;A. Mastrangelo;D. Andreini;
2022

Abstract

A major challenge during autonomous navigation in endovascular interventions is the complexity of operating in a deformable but constrained workspace with an instrument. Simulation of deformations for it can provide a cost-effective training platform for path planning. Aim of this study is to develop a realistic, auto-adaptive, and visually plausible simulator to predict vessels’ global deformation induced by the robotic catheter's contact and cyclic heartbeat motion. Based on a Position-based Dynamics (PBD) approach for vessel modeling, Particle Swarm Optimization (PSO) algorithm is employed for an auto-adaptive calibration of PBD deformation parameters and of the vessels movement due to a heartbeat. In-vitro experiments were conducted and compared with in-silico results. The end-user evaluation results were reported through quantitative performance metrics and a 5-Point Likert Scale questionnaire. Compared with literature, this simulator has an error of 0.23±0.13% for deformation and 0.30±0.85mm for the aortic root displacement. In-vitro experiments show an error of 1.35±1.38mm for deformation prediction. The end-user evaluation results show that novices are more accustomed to using joystick controllers, and cardiologists are more satisfied with the visual authenticity. The real-time and accurate performance of the simulator make this framework suitable for creating a dynamic environment for autonomous navigation of robotic catheters.
Deformable Environment; Intervention; Medical Robotics; Optimization; Simulation; Steerable Catheter
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
dic-2022
11-nov-2022
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1350453322001680-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 8.74 MB
Formato Adobe PDF
8.74 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1001776
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact