Background As pulmonary diffusing capacity is related to mortality risk and prognosis in patients with heart failure (HF), it is measured frequently. As such, it would be essential to know the week-to-week variability (reproducibility) of pulmonary diffusing capacity for carbon monoxide (DLCO) and nitric oxide (DLNO). This variability would let clinicians understand what a clinically measurable change in DLCO and DLNO would be in these patients. Methods On three different days spanning over ten weeks, 40 H F patients underwent testing for DLCO and DLNO. DLCO was determined after a 4 s and 10 s breath-hold maneuver, while DLNO was determined after a 4 s breath-hold maneuver. Results Forty heart failure patients (66 ± 10 years; BMI = 28.4 ± 4.6 kg∙m−2; 28 males), that were referred to our clinic were able to complete the protocol. DLCO (4 s breath-hold) and DLNO (4 s breath-hold) were 79 ± 19 % and 59 ± 14 % predicted, respectively. Fifty percent of patients (n = 20) were below the lower limit of normal (LLN, below the 5th percentile) for predicted DLCO (4 s), while 78 % of patients (n = 31) were below the LLN for predicted DLNO. All 16 patients that were below the LLN for DLCO were also below the LLN for DLNO. Over a ten week period, the reproducibility of DLNO (4 s) DLCO (4 s) and DLCO (10 s) was 18.9, 8.2, and 5.9 mL min mmHg-1, respectively. Conclusions The week-to-week fluctuation in DLNO (4 s), as a percentage, is less than DLCO (4 s) in patients with HF. The reproducibility of DLNO in patients with HF is like that of healthy subjects.
Variability in pulmonary diffusing capacity in heart failure / A. Magini, M. Contini, E. Spadafora, A. Apostolo, E. Salvioni, S. Barbieri, S. Sciomer, D. Andreini, F. Veglia, G.S. Zavorsky, P. Agostoni. - In: RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY. - ISSN 1569-9048. - 280(2020 Sep).
Variability in pulmonary diffusing capacity in heart failure
A. MaginiPrimo
;E. Spadafora;E. Salvioni;D. Andreini;F. Veglia;P. Agostoni
Ultimo
2020
Abstract
Background As pulmonary diffusing capacity is related to mortality risk and prognosis in patients with heart failure (HF), it is measured frequently. As such, it would be essential to know the week-to-week variability (reproducibility) of pulmonary diffusing capacity for carbon monoxide (DLCO) and nitric oxide (DLNO). This variability would let clinicians understand what a clinically measurable change in DLCO and DLNO would be in these patients. Methods On three different days spanning over ten weeks, 40 H F patients underwent testing for DLCO and DLNO. DLCO was determined after a 4 s and 10 s breath-hold maneuver, while DLNO was determined after a 4 s breath-hold maneuver. Results Forty heart failure patients (66 ± 10 years; BMI = 28.4 ± 4.6 kg∙m−2; 28 males), that were referred to our clinic were able to complete the protocol. DLCO (4 s breath-hold) and DLNO (4 s breath-hold) were 79 ± 19 % and 59 ± 14 % predicted, respectively. Fifty percent of patients (n = 20) were below the lower limit of normal (LLN, below the 5th percentile) for predicted DLCO (4 s), while 78 % of patients (n = 31) were below the LLN for predicted DLNO. All 16 patients that were below the LLN for DLCO were also below the LLN for DLNO. Over a ten week period, the reproducibility of DLNO (4 s) DLCO (4 s) and DLCO (10 s) was 18.9, 8.2, and 5.9 mL min mmHg-1, respectively. Conclusions The week-to-week fluctuation in DLNO (4 s), as a percentage, is less than DLCO (4 s) in patients with HF. The reproducibility of DLNO in patients with HF is like that of healthy subjects.File | Dimensione | Formato | |
---|---|---|---|
agostoni 3.pdf
Open Access dal 06/06/2021
Tipologia:
Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione
2.25 MB
Formato
Adobe PDF
|
2.25 MB | Adobe PDF | Visualizza/Apri |
1-s2.0-S1569904820301312-main.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
553.18 kB
Formato
Adobe PDF
|
553.18 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.