To complement RT-qPCR testing for diagnosis of severe acute respiratory syndrome coro-navirus 2 (SARS-CoV-2) infections, many countries have introduced the use of rapid antigen tests. As they generally display lower real-life performances than expected, their correct positioning as frontline screening is still controversial. Despite the lack of data from daily clinical use, third generation microfluidic assays (such as the LumiraDx SARS-CoV-2 Ag test) have recently been sug-gested to have similar performances to RT-qPCR and have been proposed as alternative diagnostic tools. By analyzing 960 nasopharyngeal swabs from 960 subjects at the emergency department ad-missions of a tertiary COVID-19 hospital, LumiraDx assay demonstrated a specificity of 97% (95% CI: 96–98), and a sensitivity of 85% (95% CI: 82–89) in comparison with RT-qPCR, which increases to 91% (95% CI: 86–95) for samples with a cycle threshold ≤ 29. Fifty false-negative LumiraDx-results were confirmed by direct quantification of genomic SARS-CoV-2 RNA through droplet-digital PCR (median (IQR) load = 5880 (1657–41,440) copies/mL). Subgenomic N and E RNAs were detected in 52% (n = 26) and 56% (n = 28) of them, respectively, supporting the presence of active viral replica-tion. Overall, the LumiraDx test complies with the minimum performance requirements of the WHO. Yet, the risk of a misrecognition of patients with active COVID-19 persists, and the need for confirmatory RT-qPCR should not be amended.

Frontline screening for sars-cov-2 infection at emergency department admission by third generation rapid antigen test: Can we spare rt-qpcr? / V. Cento, S. Renica, E. Matarazzo, M. Antonello, L. Colagrossi, F. Di Ruscio, A. Pani, D. Fanti, C. Vismara, M. Puoti, F. Scaglione, C.F. Perno, C. Alteri. - In: VIRUSES. - ISSN 1999-4915. - 13:5(2021), pp. 818.1-818.9. [10.3390/v13050818]

Frontline screening for sars-cov-2 infection at emergency department admission by third generation rapid antigen test: Can we spare rt-qpcr?

S. Renica
Secondo
;
E. Matarazzo;F. Di Ruscio;A. Pani;F. Scaglione;C.F. Perno
Penultimo
;
C. Alteri
Ultimo
2021

Abstract

To complement RT-qPCR testing for diagnosis of severe acute respiratory syndrome coro-navirus 2 (SARS-CoV-2) infections, many countries have introduced the use of rapid antigen tests. As they generally display lower real-life performances than expected, their correct positioning as frontline screening is still controversial. Despite the lack of data from daily clinical use, third generation microfluidic assays (such as the LumiraDx SARS-CoV-2 Ag test) have recently been sug-gested to have similar performances to RT-qPCR and have been proposed as alternative diagnostic tools. By analyzing 960 nasopharyngeal swabs from 960 subjects at the emergency department ad-missions of a tertiary COVID-19 hospital, LumiraDx assay demonstrated a specificity of 97% (95% CI: 96–98), and a sensitivity of 85% (95% CI: 82–89) in comparison with RT-qPCR, which increases to 91% (95% CI: 86–95) for samples with a cycle threshold ≤ 29. Fifty false-negative LumiraDx-results were confirmed by direct quantification of genomic SARS-CoV-2 RNA through droplet-digital PCR (median (IQR) load = 5880 (1657–41,440) copies/mL). Subgenomic N and E RNAs were detected in 52% (n = 26) and 56% (n = 28) of them, respectively, supporting the presence of active viral replica-tion. Overall, the LumiraDx test complies with the minimum performance requirements of the WHO. Yet, the risk of a misrecognition of patients with active COVID-19 persists, and the need for confirmatory RT-qPCR should not be amended.
antigenic test; SARS-CoV-2; rapid diagnostic test; viral load; subgenomic RNA; infectivity
Settore MED/07 - Microbiologia e Microbiologia Clinica
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
viruses-13-00818-v3.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 671.28 kB
Formato Adobe PDF
671.28 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/899777
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 14
social impact