Transbronchial biopsy (TBB) using forceps is the standard procedure to establish the presence of allograft rejection after lung transplantation. However, inadequate tissue samples, high degree of interobservers variability and possible complications seems to prevent many centers in scheduling TBB in lung transplant followup. We aimed to compare histological quality of cryobiopsy (CB) and conventional forceps biopsy (FB) for sampling lung tissue in transplants recipients.

Prospective Study of Comparison between Transbronchial Forceps Biopsy and Cryoprobe in the Diagnosis of Acute Rejection after Lung Transplantation / E. Daffrè, D. Tosi, R. Carrinola, I. Righi, F. Damarco, P. Mendogni, A. Palleschi, M. Nosotti, A. Mazzucco, C. Diotti, L. Rosso. ((Intervento presentato al 41. convegno ISHLT Annual Meeting and Scientific Sessions tenutosi a online nel 2021.

Prospective Study of Comparison between Transbronchial Forceps Biopsy and Cryoprobe in the Diagnosis of Acute Rejection after Lung Transplantation

A. Palleschi;M. Nosotti;C. Diotti;L. Rosso
2021

Abstract

Transbronchial biopsy (TBB) using forceps is the standard procedure to establish the presence of allograft rejection after lung transplantation. However, inadequate tissue samples, high degree of interobservers variability and possible complications seems to prevent many centers in scheduling TBB in lung transplant followup. We aimed to compare histological quality of cryobiopsy (CB) and conventional forceps biopsy (FB) for sampling lung tissue in transplants recipients.
apr-2021
Settore MED/21 - Chirurgia Toracica
International Society for Heart and Lung Transplantation
Prospective Study of Comparison between Transbronchial Forceps Biopsy and Cryoprobe in the Diagnosis of Acute Rejection after Lung Transplantation / E. Daffrè, D. Tosi, R. Carrinola, I. Righi, F. Damarco, P. Mendogni, A. Palleschi, M. Nosotti, A. Mazzucco, C. Diotti, L. Rosso. ((Intervento presentato al 41. convegno ISHLT Annual Meeting and Scientific Sessions tenutosi a online nel 2021.
Conference Object
File in questo prodotto:
File Dimensione Formato  
ISHLT 2021 Prospective Study of Comparison.....pdf

accesso aperto

Tipologia: Altro
Dimensione 138.78 kB
Formato Adobe PDF
138.78 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/876707
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact