If two independent sets of data are available-the piezometric heads and the related source terms for two stationary flow situations, such that the hydraulic gradients are not parallel to each other-the aquifer transmissivity can be identified with the differential system method (DSM), provided that an initial value of transmissivity is given at least at one point. In field applications, it is difficult to collect two data sets that are independent throughout the aquifer, and the results depend on the location of the point where the initial value is assigned. These difficulties are reduced if several data sets are available and the differential system is obtained either by applying a least square technique to the whole ensemble of data sets, or by choosing the "best" couple of data at each point. Numerical tests on a synthetic aquifer show that both techniques yield good results and make the DSM more robust to noise on the piezometric heads than the standard DSM applied with two data sets only.

Tomographic approach to identify transmissivity with differential system method / C. Vassena, M. Giudici, G. Ponzini, G. Parravicini, G.A. Meles. - In: JOURNAL OF HYDROLOGIC ENGINEERING. - ISSN 1084-0699. - 12:6(2007), pp. 617-625.

Tomographic approach to identify transmissivity with differential system method

C. Vassena
Primo
;
M. Giudici
Secondo
;
G. Ponzini;G. Parravicini
Penultimo
;
2007

Abstract

If two independent sets of data are available-the piezometric heads and the related source terms for two stationary flow situations, such that the hydraulic gradients are not parallel to each other-the aquifer transmissivity can be identified with the differential system method (DSM), provided that an initial value of transmissivity is given at least at one point. In field applications, it is difficult to collect two data sets that are independent throughout the aquifer, and the results depend on the location of the point where the initial value is assigned. These difficulties are reduced if several data sets are available and the differential system is obtained either by applying a least square technique to the whole ensemble of data sets, or by choosing the "best" couple of data at each point. Numerical tests on a synthetic aquifer show that both techniques yield good results and make the DSM more robust to noise on the piezometric heads than the standard DSM applied with two data sets only.
Inverse problem; hydraulic tomography; groundwater-flow; identification; parameters; model; subsurface; hydrology; transport; scale
Settore FIS/06 - Fisica per il Sistema Terra e Il Mezzo Circumterrestre
Settore GEO/12 - Oceanografia e Fisica dell'Atmosfera
2007
Article (author)
File in questo prodotto:
File Dimensione Formato  
071 Vassena et al 2007.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 847.29 kB
Formato Adobe PDF
847.29 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/38396
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact