Background: It is no longer feasible to check local International Normalized Ratios (INR) by the World Health Organization International Sensitivity Index (ISI) calibrations because the necessary manual prothrombin time technique required has generally been discarded. Objectives: An international collaborative study at 77 centers has compared local INR correction using the two alternative methods recommended in the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis guidelines: local ISI calibration and 'Direct INR'. Methods: Success of INR correction bylocal ISI calibration and with Direct INR was assessed with a set of 27 certified lyophilized plasmas (20 from patients on warfarin and seven from normals). Results: At 49 centers using human thromboplastins, 3.0% initial average local INR deviation from certified INR was reduced by local ISI calibration to 0.7% and at 25 centers using rabbit reagents, from 15.9% to 7.5%. With a minority of commercial thromboplastins, mainly 'combined' rabbit reagents, INR correction was not achieved by local ISI calibration. However, when rabbit combined reagents were excluded the overall mean INR deviation after correction was reduced further to 3.9%. In contrast, with Direct INR, mean deviation using human thromboplastins increased from 3.0% to 6.6%, but there was some reduction with rabbit reagents from 15.9% to 10% (12.3% with combined reagents excluded). Conclusions: Local ISI calibration gave INR correction for the majority of PT systems but failed at the small number using combined rabbit reagents suggesting a need for a combined reference thromboplastin. Direct INR correction was disappointing but better than local ISI calibration with combined rabbit reagents. Interlaboratory variability was improved by both procedures with human reagents only.

Comparison of local International Sensitivity Index calibration and 'Direct INR' methods in correction of locally reported International Normalized Ratios : an international study / L. Poller, M. Keown, S. Ibrahim, A.M.H.P. van den Besselaar, C. Roberts, K. Stevenson, A. Tripodi, A. Pattison, J. Jespersen, European concerted action on anticoagulation. - In: JOURNAL OF THROMBOSIS AND HAEMOSTASIS. - ISSN 1538-7933. - 5:5(2007), pp. 1002-1009.

Comparison of local International Sensitivity Index calibration and 'Direct INR' methods in correction of locally reported International Normalized Ratios : an international study

A. Tripodi;
2007

Abstract

Background: It is no longer feasible to check local International Normalized Ratios (INR) by the World Health Organization International Sensitivity Index (ISI) calibrations because the necessary manual prothrombin time technique required has generally been discarded. Objectives: An international collaborative study at 77 centers has compared local INR correction using the two alternative methods recommended in the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis guidelines: local ISI calibration and 'Direct INR'. Methods: Success of INR correction bylocal ISI calibration and with Direct INR was assessed with a set of 27 certified lyophilized plasmas (20 from patients on warfarin and seven from normals). Results: At 49 centers using human thromboplastins, 3.0% initial average local INR deviation from certified INR was reduced by local ISI calibration to 0.7% and at 25 centers using rabbit reagents, from 15.9% to 7.5%. With a minority of commercial thromboplastins, mainly 'combined' rabbit reagents, INR correction was not achieved by local ISI calibration. However, when rabbit combined reagents were excluded the overall mean INR deviation after correction was reduced further to 3.9%. In contrast, with Direct INR, mean deviation using human thromboplastins increased from 3.0% to 6.6%, but there was some reduction with rabbit reagents from 15.9% to 10% (12.3% with combined reagents excluded). Conclusions: Local ISI calibration gave INR correction for the majority of PT systems but failed at the small number using combined rabbit reagents suggesting a need for a combined reference thromboplastin. Direct INR correction was disappointing but better than local ISI calibration with combined rabbit reagents. Interlaboratory variability was improved by both procedures with human reagents only.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/33588
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact