Purpose: To quantitatively evaluate the impact of thoracic endovascular aortic repair (TEVAR) on aortic hemodynamics, focusing on the implications of a bird-beak configuration.Methods: Pre- and postoperative CTA images from a patient treated with TEVAR for postdissecting thoracic aortic aneurysm were used to evaluate the anatomical changes induced by the stent-graft and to generate the computational network essential for computational fluid dynamics (CFD) analysis. These analyses focused on the bird-beak configuration, flow distribution into the supra-aortic branches, and narrowing of the distal descending thoracic aorta. Three different CFD analyses (A: preoperative lumen, B: postoperative lumen, and C: postoperative lumen computed without stenosis) were compared at 3 time points during the cardiac cycle (maximum acceleration of blood flow, systolic peak, and maximum deceleration of blood flow).Results: Postoperatively, disturbance of flow was reduced at the bird-beak location due to boundary conditions and change of geometry after TEVAR. Stent-graft protrusion with partial coverage of the origin of the left subclavian artery produced a disturbance of flow in this vessel. Strong velocity increase and flow disturbance were found at the aortic narrowing in the descending thoracic aorta when comparing B and C, while no effect was seen on aortic arch hemodynamics.Conclusion: CFD may help physicians to understand aortic hemodynamic changes after TEVAR, including the change in aortic arch geometry, the effects of a bird-beak configuration, the supra-aortic flow distribution, and the aortic true lumen dynamics. This study is the first step in establishing a computational framework that, when completed with patient-specific data, will allow us to study thoracic aortic pathologies and their endovascular management.

Aortic hemodynamics after thoracic endovascular aortic repair, with particular attention to the bird-beak configuration / G.H.W. Van Bogerijen, F. Auricchio, M. Conti, A. Lefieux, A. Reali, A. Veneziani, J.L. Tolenaar, F.L. Moll, V. Rampoldi, S. Trimarchi. - In: JOURNAL OF ENDOVASCULAR THERAPY. - ISSN 1526-6028. - 21:6(2014 Dec), pp. 791-802.

Aortic hemodynamics after thoracic endovascular aortic repair, with particular attention to the bird-beak configuration

V. Rampoldi
Penultimo
;
S. Trimarchi
Ultimo
2014

Abstract

Purpose: To quantitatively evaluate the impact of thoracic endovascular aortic repair (TEVAR) on aortic hemodynamics, focusing on the implications of a bird-beak configuration.Methods: Pre- and postoperative CTA images from a patient treated with TEVAR for postdissecting thoracic aortic aneurysm were used to evaluate the anatomical changes induced by the stent-graft and to generate the computational network essential for computational fluid dynamics (CFD) analysis. These analyses focused on the bird-beak configuration, flow distribution into the supra-aortic branches, and narrowing of the distal descending thoracic aorta. Three different CFD analyses (A: preoperative lumen, B: postoperative lumen, and C: postoperative lumen computed without stenosis) were compared at 3 time points during the cardiac cycle (maximum acceleration of blood flow, systolic peak, and maximum deceleration of blood flow).Results: Postoperatively, disturbance of flow was reduced at the bird-beak location due to boundary conditions and change of geometry after TEVAR. Stent-graft protrusion with partial coverage of the origin of the left subclavian artery produced a disturbance of flow in this vessel. Strong velocity increase and flow disturbance were found at the aortic narrowing in the descending thoracic aorta when comparing B and C, while no effect was seen on aortic arch hemodynamics.Conclusion: CFD may help physicians to understand aortic hemodynamic changes after TEVAR, including the change in aortic arch geometry, the effects of a bird-beak configuration, the supra-aortic flow distribution, and the aortic true lumen dynamics. This study is the first step in establishing a computational framework that, when completed with patient-specific data, will allow us to study thoracic aortic pathologies and their endovascular management.
computational fluid dynamics; biomechanics; aorta; thoracic endovascular aortic repair; bird-beak; stent-graft; flow disturbance; true lumen narrowing
Settore MED/22 - Chirurgia Vascolare
dic-2014
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/284597
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 32
social impact