Three automatic approaches to ventricular repolarisation duration measurement (R-Tapex, R-T(end threshold) and R-T(end fitting) methods) are compared on computer-generated and real ECG signals, in relation to their reliability in the presence of the most common electrocardiographic artefacts (i.e. additive broadband noise and additive and multiplicative periodical disturbances). Simulations permit the evaluation of the amount of R-T beat-to-beat variability induced by the artefacts. The R-T(end threshold) method performs better than the R-T(end fitting) one, and, hence, the latter should be used with caution when R-T(end) variability is addressed. Whereas the R-Tapex method is more robust with regard to broadband noise than the R-T(end threshold) one, the reverse situation is observed in the presence of periodical amplitude modulations. A high level of broadband noise dose not prevent the detection of the central frequency of underlying R-T periodical changes. Comparison between the power spectra of the beat-to-beat R-T variability series obtained from three orthogonal ECG leads (X,Y,Z) is used to assess the amount of real and artefactual variability in 13 normal subjects at rest. The R-Tapex series displays rhythms at high frequency (HF) with a percentage power on the Z lead (57.1 +/- 4.9) greater than that on the X and Y leads (41.9 +/- 4.6 and 46.1 +/- 4.9, respectively), probably because of respiratory-related artefacts affecting the Z lead more remarkably. More uniform HF power distributions over X,Y,Z leads are observed in the R-T(end threshold) series (31.8 +/- 3.8, 39.2 +/- 4.1 and 35.1 +/- 4.2, respectively), thus suggesting minor sensitivity of the R-T(end threshold) measure to respiratory-related artefacts.

Performance assessment of standard algorithms for dynamic RT interval measurement: comparison between RTapex and RTend approach / A. Porta, G. Baselli, F. Lombardi, S. Cerutti, R. Antolini, M. Del Greco, F. Ravelli, G. Nollo. - In: MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING. - ISSN 0140-0118. - 36:1(1998 Jan), pp. 35-42.

Performance assessment of standard algorithms for dynamic RT interval measurement: comparison between RTapex and RTend approach

A. Porta
Primo
;
F. Lombardi;
1998

Abstract

Three automatic approaches to ventricular repolarisation duration measurement (R-Tapex, R-T(end threshold) and R-T(end fitting) methods) are compared on computer-generated and real ECG signals, in relation to their reliability in the presence of the most common electrocardiographic artefacts (i.e. additive broadband noise and additive and multiplicative periodical disturbances). Simulations permit the evaluation of the amount of R-T beat-to-beat variability induced by the artefacts. The R-T(end threshold) method performs better than the R-T(end fitting) one, and, hence, the latter should be used with caution when R-T(end) variability is addressed. Whereas the R-Tapex method is more robust with regard to broadband noise than the R-T(end threshold) one, the reverse situation is observed in the presence of periodical amplitude modulations. A high level of broadband noise dose not prevent the detection of the central frequency of underlying R-T periodical changes. Comparison between the power spectra of the beat-to-beat R-T variability series obtained from three orthogonal ECG leads (X,Y,Z) is used to assess the amount of real and artefactual variability in 13 normal subjects at rest. The R-Tapex series displays rhythms at high frequency (HF) with a percentage power on the Z lead (57.1 +/- 4.9) greater than that on the X and Y leads (41.9 +/- 4.6 and 46.1 +/- 4.9, respectively), probably because of respiratory-related artefacts affecting the Z lead more remarkably. More uniform HF power distributions over X,Y,Z leads are observed in the R-T(end threshold) series (31.8 +/- 3.8, 39.2 +/- 4.1 and 35.1 +/- 4.2, respectively), thus suggesting minor sensitivity of the R-T(end threshold) measure to respiratory-related artefacts.
Automatic R-T measurement; Q-T interval; R-T variability; Time- and frequency-domain analysis; Ventricular repolarisation duration
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
Settore MED/09 - Medicina Interna
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
gen-1998
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/22291
Citazioni
  • ???jsp.display-item.citation.pmc??? 24
  • Scopus 86
  • ???jsp.display-item.citation.isi??? 80
social impact