An ELISA method was developed for the measurement of toxoplasma IgG antibodies in human serum using antigen-coated polystyrene beads as a solid phase and anti human IgG-horse radish peroxidase conjugate as an enzymatic tracer. In order to assess ELISA sensitivity and specificity, a between methods comparison was made using 'conventional' serological tests as reference (dye-test, crossover-linked immunoassay, passive haemagglutination, indirect immunofluorescence). From an analysis of the group classifications obtained some considerations emerged: the ELISA specificity looks comparable with that of the 'reference' tests, as no sample classified as negative by all these tests was ELISA-positive, and vice versa; ELISA appears to correlate better with haemagglutination and immunofluorescence, on the basis of the respective class frequencies; in particular, the number of positives, which is much lower for the dye-test and crossover-linked immunoassay, suggests that a higher sensitivity is reached in the former cases.

ELISA for toxoplasma antibody detection: a comparison with other serodiagnostic tests / A.BALSARI ,G. POLI ,V. MOLINA ,M. DOVIS , E.PETRUZZELLI , A. BONIOLO, E. ROLLERI. - In: AMERICAN JOURNAL OF CLINICAL PATHOLOGY. - ISSN 0002-9173. - 33:7(1980), pp. 640-643.

ELISA for toxoplasma antibody detection: a comparison with other serodiagnostic tests

G. POLI
Secondo
;
1980

Abstract

An ELISA method was developed for the measurement of toxoplasma IgG antibodies in human serum using antigen-coated polystyrene beads as a solid phase and anti human IgG-horse radish peroxidase conjugate as an enzymatic tracer. In order to assess ELISA sensitivity and specificity, a between methods comparison was made using 'conventional' serological tests as reference (dye-test, crossover-linked immunoassay, passive haemagglutination, indirect immunofluorescence). From an analysis of the group classifications obtained some considerations emerged: the ELISA specificity looks comparable with that of the 'reference' tests, as no sample classified as negative by all these tests was ELISA-positive, and vice versa; ELISA appears to correlate better with haemagglutination and immunofluorescence, on the basis of the respective class frequencies; in particular, the number of positives, which is much lower for the dye-test and crossover-linked immunoassay, suggests that a higher sensitivity is reached in the former cases.
Settore VET/05 - Malattie Infettive degli Animali Domestici
1980
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/198763
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 34
  • ???jsp.display-item.citation.isi??? ND
social impact