The usual methods for prenatal diagnosis of beta-thalassemia and other hemoglobinopathies by assay of fetal blood erythrocytes are either complex (analysis of globin chains synthesis by carboxymethylcellulose chromatography) or only semiquantitative [isoelectric focusing of hemoglobin (Hb)]. To further simplify the diagnostic procedure and to obtain quantitative data, we measured the small concentrations of Hb A in fetal erythrocytes by using a high-pressure liquid chromatography (HPLC) instrument (DIAMAT-TM; Bio-Rad) equipped with the new column proposed for measuring Hb A2. We analyzed 212 uncontaminated fetal blood samples obtained by cordocentesis between the 18th and 22nd weeks of pregnancy, using the HPLC procedure, and compared the results with those obtained by the above-named methods. The Hb A values obtained ranged between 0% and 8.5%; they were less than or equal to 1.8% in 44 fetuses affected by homozygous beta-thalassemia and greater than 2.5% in 168 unaffected fetuses. The method was simple, rapid, and reproducible (CV 3.2%) and there was good correlation between Hb A concentrations determined by HPLC and the beta/gamma ratio determined by carboxymethylcellulose chromatography (r = 0.7687; P less than 0.0001). No false-negative or false-positive results were observed, and there was no overlap of values between affected and unaffected fetuses.

Nonradioactive quantification of low concentrations of hemoglobin A by HPLC for midtrimester prenatal diagnosis of beta-thalassemia / R. Maiavacca, S. Tedeschi, A. Mosca, S. Calmi, P. De Leonardis, C. Todaro, G. Zuliani, M. Buscaglia, A. Cantù-Rajnoldi. - In: CLINICAL CHEMISTRY. - ISSN 0009-9147. - 38:9(1992 Sep), pp. 1906-8-1908.

Nonradioactive quantification of low concentrations of hemoglobin A by HPLC for midtrimester prenatal diagnosis of beta-thalassemia

A. Mosca;
1992

Abstract

The usual methods for prenatal diagnosis of beta-thalassemia and other hemoglobinopathies by assay of fetal blood erythrocytes are either complex (analysis of globin chains synthesis by carboxymethylcellulose chromatography) or only semiquantitative [isoelectric focusing of hemoglobin (Hb)]. To further simplify the diagnostic procedure and to obtain quantitative data, we measured the small concentrations of Hb A in fetal erythrocytes by using a high-pressure liquid chromatography (HPLC) instrument (DIAMAT-TM; Bio-Rad) equipped with the new column proposed for measuring Hb A2. We analyzed 212 uncontaminated fetal blood samples obtained by cordocentesis between the 18th and 22nd weeks of pregnancy, using the HPLC procedure, and compared the results with those obtained by the above-named methods. The Hb A values obtained ranged between 0% and 8.5%; they were less than or equal to 1.8% in 44 fetuses affected by homozygous beta-thalassemia and greater than 2.5% in 168 unaffected fetuses. The method was simple, rapid, and reproducible (CV 3.2%) and there was good correlation between Hb A concentrations determined by HPLC and the beta/gamma ratio determined by carboxymethylcellulose chromatography (r = 0.7687; P less than 0.0001). No false-negative or false-positive results were observed, and there was no overlap of values between affected and unaffected fetuses.
Pregnancy Trimester, Second; Homozygote; Humans; Hemoglobin A; Chromatography, Ion Exchange; Prenatal Diagnosis; Thalassemia; Female; Chromatography, High Pressure Liquid; Pregnancy
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
set-1992
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/192364
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 13
  • ???jsp.display-item.citation.isi??? ND
social impact