This collaborative study was designed to assess the performance of commercial methods for protein S (PS) antigen measurement. Twenty-five different samples were distributed deep-frozen (24 plasmas) or lyophilized (one plasma) to five laboratories. They were analyzed blind in each laboratory by the method used locally and by three commercial methods which included two electroimmunoassays (EIA), Asseraplate-PS (Diagnostica Stago), Rellplate-S (American Diagnostica) and an ELISA system, Asserachrom-PS (Diagnostica Stago). 1. Reproducibility. Average between-laboratory coefficients of variation were 15.4%, 17.6% and 25.3% for Asserachrom-PS, Asseraplate-PS and Rellplate-S. 2. Specificity. Results of all methods showed that PS is underestimated when C4b binding protein is high. This influence was particularly evident for the ELISA Asserachrom-PS and disappeared when the antibody-antigen incubation period was prolonged to overnight. 3. Sensitivity. In all laboratories ELISA detected even the lowest PS concentration (4U/dl), whereas the two EIAs were less sensitive (lower detection limit 14U/dl). All methods and laboratories correctly diagnosed a plasma sample from a PS congenitally deficient patient. Conclusions. This study shows that better standardization of PS immunoassays is necessary to improve accuracy and reduce interlaboratory variability before a candidate plasma standard can be successfully calibrated in an international collaborative study.

Multicenter evaluation of three commercial methods for measuring protein S antigen / A. Tripodi, R.M. Bertina, J. Conard, I. Pabinger, N. Sala, P.M. Mannucci. - In: THROMBOSIS AND HAEMOSTASIS. - ISSN 0340-6245. - 68:2(1992), pp. 149-154.

Multicenter evaluation of three commercial methods for measuring protein S antigen

A. Tripodi
Primo
;
1992

Abstract

This collaborative study was designed to assess the performance of commercial methods for protein S (PS) antigen measurement. Twenty-five different samples were distributed deep-frozen (24 plasmas) or lyophilized (one plasma) to five laboratories. They were analyzed blind in each laboratory by the method used locally and by three commercial methods which included two electroimmunoassays (EIA), Asseraplate-PS (Diagnostica Stago), Rellplate-S (American Diagnostica) and an ELISA system, Asserachrom-PS (Diagnostica Stago). 1. Reproducibility. Average between-laboratory coefficients of variation were 15.4%, 17.6% and 25.3% for Asserachrom-PS, Asseraplate-PS and Rellplate-S. 2. Specificity. Results of all methods showed that PS is underestimated when C4b binding protein is high. This influence was particularly evident for the ELISA Asserachrom-PS and disappeared when the antibody-antigen incubation period was prolonged to overnight. 3. Sensitivity. In all laboratories ELISA detected even the lowest PS concentration (4U/dl), whereas the two EIAs were less sensitive (lower detection limit 14U/dl). All methods and laboratories correctly diagnosed a plasma sample from a PS congenitally deficient patient. Conclusions. This study shows that better standardization of PS immunoassays is necessary to improve accuracy and reduce interlaboratory variability before a candidate plasma standard can be successfully calibrated in an international collaborative study.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
1992
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189455
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 19
  • ???jsp.display-item.citation.isi??? ND
social impact