The std. aq. potentials of the mercury(II) oxide electrode and of the silver(I) oxide electrode covering the temp. range from 283 to 318 K were critically analyzed (with special attention to the std. states implied) and redetd.: as a result, recommended values are tabulated for both the resp. «acid» and «basic» std. potentials. From these potentials, accurate values for the std. soly. products of the corresponding hydroxides, Hg(OH)2 and AgOH, were also derived. The usefulness and applications of the mercury(II) oxide electrode, as well as the limited applicability of the silver(I) oxide electrode, are described.
Mercury(II) oxide and silver(I) oxide electrodes in aqueous solutions / S. Rondinini, P. Longhi, P.R. Mussini, T. Mussini. - In: PURE AND APPLIED CHEMISTRY. - ISSN 0033-4545. - 66:3(1994 Mar), pp. 641-647. (Intervento presentato al convegno International Conference on Thermodynamics of Solutions and Biological Systems tenutosi a New Delhi nel 1993) [10.1351/pac199466030641].
Mercury(II) oxide and silver(I) oxide electrodes in aqueous solutions
S. RondininiPrimo
;P. LonghiSecondo
;P.R. MussiniPenultimo
;T. MussiniUltimo
1994
Abstract
The std. aq. potentials of the mercury(II) oxide electrode and of the silver(I) oxide electrode covering the temp. range from 283 to 318 K were critically analyzed (with special attention to the std. states implied) and redetd.: as a result, recommended values are tabulated for both the resp. «acid» and «basic» std. potentials. From these potentials, accurate values for the std. soly. products of the corresponding hydroxides, Hg(OH)2 and AgOH, were also derived. The usefulness and applications of the mercury(II) oxide electrode, as well as the limited applicability of the silver(I) oxide electrode, are described.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.