Reparative surgery of the aortic root functional unit (ARFU) allows for a better preservation of the functionality of the native structure compared to prosthesis implantation. Post-operative results are satisfactory, whereas mid- and long-term results are challenging, for example in terms of cusps prolapse recurrence. At the Cardiothoracic Surgery Unit of the Sacco Hospital, a new surgical technique aimed at the stabilization in time of the results of standard ARFU repair operations has been applied. This technique, inspired by the mitral neo-chordae (NC) implantation, consists of implanting an e-PTFE suture thread between the prolapsed cusp and the sinotubular junction. Aim of this study was to assess the influence of NC implantation on the ARFU functioning by evaluating with an owned pulsatile in vitro apparatus the force magnitude acting on the NC and the dynamic behavior of porcine ARFUs treated according to the operating-room procedures. The maximum recorded values of the mean and peak diastolic forces were 0.064 and 0.186 N, respectively, and were linearly dependent upon the mean diastolic pressure across the valve. In addition, the measurements of the opening–closing times and valve leakage volumes, performed at pre- and post-surgeries, yielded that the valve functionality was not significantly influenced by NC implantation.

In Vitro Study of Aortic Valves Treated with Neo-Chordae Grafts : Hydrodynamics and Tensile Force Measurements / R. Vismara, C. Antona, A. Mangini, M. Cervo, M. Contino, E. Bosisio, A. Redaelli, G.B. Fiore. - In: ANNALS OF BIOMEDICAL ENGINEERING. - ISSN 0090-6964. - 39:3(2011), pp. 1024-1031. [10.1007/s10439-010-0235-8]

In Vitro Study of Aortic Valves Treated with Neo-Chordae Grafts : Hydrodynamics and Tensile Force Measurements

C. Antona
Secondo
;
M. Contino;
2011

Abstract

Reparative surgery of the aortic root functional unit (ARFU) allows for a better preservation of the functionality of the native structure compared to prosthesis implantation. Post-operative results are satisfactory, whereas mid- and long-term results are challenging, for example in terms of cusps prolapse recurrence. At the Cardiothoracic Surgery Unit of the Sacco Hospital, a new surgical technique aimed at the stabilization in time of the results of standard ARFU repair operations has been applied. This technique, inspired by the mitral neo-chordae (NC) implantation, consists of implanting an e-PTFE suture thread between the prolapsed cusp and the sinotubular junction. Aim of this study was to assess the influence of NC implantation on the ARFU functioning by evaluating with an owned pulsatile in vitro apparatus the force magnitude acting on the NC and the dynamic behavior of porcine ARFUs treated according to the operating-room procedures. The maximum recorded values of the mean and peak diastolic forces were 0.064 and 0.186 N, respectively, and were linearly dependent upon the mean diastolic pressure across the valve. In addition, the measurements of the opening–closing times and valve leakage volumes, performed at pre- and post-surgeries, yielded that the valve functionality was not significantly influenced by NC implantation.
neo-chordae technique; aortic valve surgical repair; in vitro test; pulsatile hydrodynamics; aortic root functional unit
Settore MED/23 - Chirurgia Cardiaca
Settore ING-IND/34 - Bioingegneria Industriale
2011
Article (author)
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs10439-010-0235-8.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 461.43 kB
Formato Adobe PDF
461.43 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/170879
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact